English
Language : 

LBV320-XXHNDRAMX00700 Datasheet, PDF (2/6 Pages) SICK AG – LEVEL SENSORS
LBV320-XXHNDRAMX00700 | LBV300
LEVEL SENSORS
A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T
Ordering information
Type
LBV320-XXHNDRAMX00700
Other models and accessories www.sick.com/LBV300
Illustration may differ
Part no.
6038532
Detailed technical data
Features
Medium
Measurement
Probe length
Process pressure
Process temperature
Fill material density
Particle size
Tensile strength
Performance
Accuracy of sensor element
Repeatability
Response time
Electronics
Power consumption
Initialization time
VDE protection class 1
Electrical connection
Supply voltage
Hysteresis
Output current
Inductive load
Capacitive load
Contact load
Enclosure rating
Mechanics
Process connection
Housing material
2
FLUID SENSORS | SICK
Bulk solids
Switch
700 mm
–1 bar ... 6 bar
–40 °C ... +150 °C
≥ 0.008
< 10 mm
≤ 3,000 N
± 10 mm
≤ 5 mm
500 ms when covered / 1,000 ms when uncovered
5 mA ... 30 mA
<2s
✔
M20 x 1.5
Double relay (DPDT): 20 V DC ... 72 V DC / 20 V AC ... 253 V AC
10 mm
> 10 µA; < 3A AC, 1A DC
750 VA 54 W
750 VA 54 W
Min. 50 mW / max. 750 VA, 54 W
IP 66 / IP 67
1 1/2" NPT PN 25 / stainless steel 316L
Aluminum
Online data sheet | 2016-05-17 16:55:06
Subject to change without notice