FFUS10-1G1SR Datasheet, PDF (2/5 Pages) SICK AG – FLOW SENSORS
FFUS10-1G1SR | FFU
FLOW SENSORS
A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T
Ordering information
Type
FFUS10-1G1SR
Other models and accessories www.sick.com/FFU
Illustration may differ
Part no.
6043743
Features
Medium
Nominal width measuring tube
Process temperature
Process pressure
Fluids
DN 10
0 °C ... +80 °C
Max. 16 bar
Performance
Minimim flow
Maximum flow
Inlet zone
Output zone
Conductivity
Accuracy of sensor element
Reproducibility
Resolution
≤ 0.3 l/min
≤ 21 l/min
10 cm
0 cm
No limitation
2 % (of final value) 1)
≤ 0.5 %
0.003 l/min
1) Reference condition: Water, zero gas, measuring tube completely full, no cavitation, temperature of medium 20 °C, ambient temperature 20 °C ... 25 °C, compli-
ance with inlet and outlet zones, warm-up time for electronics: 30 min.
Electronics
Supply voltage
Residual ripple
Power consumption
Initialization time
Protection class
Electrical connection
18 V DC ... 30 V DC 1)
≤ 5 Vpp 2)
≤ 180 mA 3)
≤5s
III
M12 round connector x 1, 8-pin
1) All connections are polarity protected. All outputs are overload and short-circuit protected.
2) May not exceed or fall below Uv tolerances.
3) Without load.
4) There are 100 mA for each output pnp and npn available.
5) Analog output and display.
2
FLUID SENSORS | SICK
Online data sheet | 2017-02-08 13:58:08
Subject to change without notice