English
Language : 

DT50-P2113 Datasheet, PDF (2/6 Pages) SICK AG – MID RANGE DISTANCE SENSORS
DT50-P2113 | Dx50
MID RANGE DISTANCE SENSORS
A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T
Ordering information
Type
DT50-P2113
Other models and accessories www.sick.com/Dx50
Part no.
1047314
Detailed technical data
Performance
Measuring range
Resolution
Repeatability
Accuracy
Response time
Output time
Light source
Laser class
Typ. light spot size (distance)
Additional function
Laser service life (MTTF at 25 °C)
200 mm ... 20,000 mm, 90 % remission
200 mm ... 8,500 mm, 18 % remission
200 mm ... 5,000 mm, 6 % remission
1 mm
3 mm / 2 mm / 1 mm 1) 2) 3)
± 7 mm 4)
15 ms / 30 ms / 80 ms 3) 5)
≥ 2 ms 6)
Laser, red
2 (EN 60825-1) 7)
15 mm x 15 mm (10 m)
Set moving average fast/medium/slow, switching mode: distance to object (DtO), teach-in,
scaling and inversion of switching output, set hysteresis, teach-in, scaling and inversion of ana-
log output, Multifunctional input: laser off / external teach / deactivated, switch-off display, re-
set to factory default, lock user interface
100,000 h
1) Equivalent to 1 σ.
2) 6 % ... 90 % remission.
3) Dependent on the averaging setting: fast/medium/slow.
4) 90 % remission.
5) Lateral entry of the object into the measuring range.
6) Continuous change of distance in measuring range.
7) Wavelength: 658 nm; max. output: 180 mW; pulse duration: 5 ns; duty cycle: 1/200.
Interfaces
Analog output
1 x 4 mA ... 20 mA (≤ 300 Ω)
1) Output Q short-circuit protected.
2) PNP: HIGH = VS - (< 2.5 V) / LOW = 0 V.
3) Response time ≤ 15ms.
4) PNP: HIGH = VS / LOW = ≤ 2.5 V.
2
DISTANCE SENSORS | SICK
Online data sheet | 2016-03-17 13:18:11
Subject to change without notice