English
Language : 

DT20-P244B Datasheet, PDF (2/6 Pages) SICK AG – DISPLACEMENT MEASUREMENT SENSORS
DT20-P244B | DT20 Hi
DISPLACEMENT MEASUREMENT SENSORS
A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T
Ordering information
Type
DT20-P244B
Other models and accessories www.sick.com/DT20_Hi
Part no.
1040406
Detailed technical data
Performance
Measuring range
Resolution
Repeatability
Linearity
Response time
Measuring frequency
Light source
Laser class
Typ. light spot size (distance)
Additional function
100 mm ... 300 mm, 6 % ... 90 % remission
200 µm 1)
1 mm / 0.5 mm / 0.25 mm 1) 2) 3)
± 1 mm 4) 3)
2,5 ms / 10 ms / 40 ms 2)
400 Hz
Laser, red
2 (EN 60825-1)
3 mm x 6 mm (300 mm)
Set moving average fast/medium/slow, switching mode: distance to object (DtO), teach-in of
switching output, Invertable switching output, teach-in of analog output, Invertable analog out-
put, Multifunctional input: laser off / external teach-in / deactivated, switch-off display, lock
user interface
1) 6 % ... 90 % remission.
2) Dependent on the averaging setting: fast/medium/slow.
3) When calibrated in the application regularly.
4) 90 % remission.
Interfaces
Analog output
Resolution analog output
Switching output
Multifunctional input (MF)
Data interface
1 x 4 mA ... 20 mA (≤ 300 Ω)
12 bit
1 x PNP (100 mA) 1)
1 x MF 2)
1 x 4 mA ... 20 mA (< 300 Ω)
1) PNP: HIGH = VS - (< 2 V) / LOW = < 2 V; NPN: HIGH = < 2 V / LOW = VS.
2) MF can be used as laser-off, external teach-in or deactivated.
2
DISTANCE SENSORS | SICK
Online data sheet | 2016-03-17 13:18:11
Subject to change without notice