Ordering information
Type
DT20-P130B4000
Other models and accessories www.sick.com/DT20
Part no.
1028722
Detailed technical data
Performance
Measuring range
Resolution
Repeatability
Accuracy
Response time
Light source
Typ. light spot size (distance)
Additional function
Laser service life (MTTF at 25 °C)
400 mm ... 1,000 mm, 18 % ... 90 % remission 1)
1 mm / 2 mm 2)
± 1.5 mm / ± 3 mm 3)
± 4 mm 4) 5)
10 ms / 15 ms 2)
LED, infrared
15 mm x 15 mm (at 1 m)
Plug-and-play, Customer specific scaled measuring range, Switching output to monitor the
measuring range
100,000 h
1) ´On 6 % remission the maximal measurable distance is 820 mm.
2) Depending on measurement range: 90 ... 600 mm / > 600 mm.
3) 18 % ... 90 % remission.
4) 6 % ... 90 % remission.
5) ± 4 mm up to 600 mm; ≤ ±7 mm at distance < 600 mm; see accuracy diagram.
Interfaces
Analog output
1 x 4 mA ... 20 mA (≤ 300 Ω)
Switching output
1 x PNP (100 mA) 1)
1) PNP: HIGH = VS - (< 2 V) / LOW = 0 V.
Mechanics/electronics
Supply voltage Vs
Ripple
Power consumption
DC 10 V ... 30 V 1)
≤ 5 Vpp 2)
≤ 1.5 W 3)
1) Limit values, reverse-polarity protected, operation in short-circuit protected network: max. 8 A.
2) May not fall short of or exceed VS tolerances.
3) Without load.
2
DISTANCE SENSORS | SICK
Online data sheet | 2016-03-17 13:18:11
Subject to change without notice