Ordering information
Type
DS60-N41211
Other models and accessories www.sick.com/Dx60
Detailed technical data
Performance
Measuring range
Response time
Switching frequency
Light source
Laser class
Typ. light spot size (distance)
Additional function
Laser service life (MTTF at 25 °C)
80 mm ... 6,000 mm, 90 % remission 1)
80 mm ... 5,000 mm, 18 % remission 1)
80 mm ... 2,600 mm, 6 % remission 1)
50 ms
10 Hz
Laser, red
2 (EN 60825-1)
9 mm x 9 mm (at 4.5 m)
Invertable switching output
50,000 h
1) Teach-in from 200 … 6,000 mm.
Interfaces
Switching output
2x NPN (100 mA) 1) 2)
1) Output Q short-circuit protected.
2) NPN: HIGH = < 2.5 V / LOW = VS.
Mechanics/electronics
Supply voltage Vs
Ripple
Power consumption
Connection type
Weight
DC 18 V ... 30 V 1)
≤ 5 Vpp 2)
≤ 3 W 3)
Male connector, M12, 5-pin
202 g
1) Limit values, reverse-polarity protected, operation in short-circuit protected network: max. 8 A.
2) May not fall short of or exceed VS tolerances.