Ordering information
Type
DME4000-127
Other models and accessories www.sick.com/DME4000
Detailed technical data
Performance
Measuring range
Resolution
Repeatability
Accuracy
Output time
Light source
Laser class
Typ. light spot size (distance)
Max. movement speed
0.15 m ... 50 m, on reflective tape "Diamond Grade"
0.25 mm ... 4 mm 1)
1 mm 2) 3)
± 3 mm
2 ms
Laser, red 4)
2 (EN 60825-1 / CDRH)
130 mm (at 70 m)
270 mm (at 150 m)
360 mm (at 220 m)
10 m/s
1) For HIPERFACE® data interface 1/32 mm ... 1/2 mm, for sin/cos 0.25 mm ... 4 mm.
2) On reflective tape "Diamond Grade"
3) Statistical error 1 σ, environmental conditions constant, min. warm-up time 10 min.
4) Average service life of 50,000 h at TA = +25 °C.
Interfaces
Switching output
Push-pull: PNP/NPN (100 mA) 1)
Multifunctional input (MF)
1 x MF 2) 3)
Data interface
HIPERFACE
1) HIGH = > VS - 3 V / LOW = < 2 V.
2) HIGH = > 12 V / LOW = < 3 V.
3) Not reverse-polarity protected.
Mechanics/electronics
Supply voltage Vs
DC 18 V ... 30 V, limit values
1) May not fall short of or exceed VS tolerances.
2) For HIPERFACE®, after loss of reflector < 1 s at Vmax < 1 m/s.
3) Short-circuit protected, overload-protected. Max. 100 nF / 20 mH.
2
DISTANCE SENSORS | SICK
Part no.
1029812
Online data sheet | 2016-03-17 13:18:11
Subject to change without notice