English
Language : 

UF5A Datasheet, PDF (1/2 Pages) Changzhou Shunye Electronics Co.,Ltd. – SURFACE MOUNT ULTRA FAST RECTIFIER
UF5A THRU UF5M
SURFACE MOUNT ULTRA FAST RECTIFIER
Reverse Voltage - 50 to 1000 Volts Forward Current - 5.0 Amperes
0.126 (3.20)
0.114 (2.90)
DO-214AB
0.280(7.11)
0.260(6.60)
0.245(6.22)
0.220(5.59)
0.012(0.305)
0.006(0.152)
FEATURES
The plastic package carries Underwriters Laboratory
Flammability Classification 94V-0
For surface mounted applications
Low reverse leakage
Built-in strain relief,ideal for automated placement
High forward surge current capability
High temperature soldering guaranteed:
250 C/10 seconds at terminals
Glass passivated chip junction
0.103(2.62)
0.079(2.06)
0.060(1.52)
0.030(0.76)
0.008(0.203)MAX.
0.320(8.13)
0.305(7.75)
MECHANICAL DATA
Case: JEDEC DO-214AB molded plastic body over passivated chip
Terminals: Solder plated, solderable per MIL-STD-750,
Method 2026
Polarity: Color band denotes cathode end
Mounting Position: Any
Weight:0.007 ounce, 0.25grams
Dimensions in inches and (millimeters)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25 C ambient temperature unless otherwise specified.
Single phase half-wave 60Hz,resistive or inductive load,for capacitive load current derate by 20%.
SYMBOLS UF5A UF5B UF5D UF5G UF5J
Maximum repetitive peak reverse voltage
Maximum RMS voltage
Maximum DC blocking voltage
VRRM
50
VRMS
35
VDC
50
Maximum average forward rectified current
I(AV)
at TL=55 C
Peak forward surge current
8.3ms single half sine-wave superimposed on
IFSM
rated load (JEDEC Method)
Maximum instantaneous forward voltage at 5.0A
VF
Maximum DC reverse current TA=25 C
at rated DC blocking voltage TA=100 C
IR
Maximum reverse recovery time (NOTE 1)
trr
Typical junction capacitance (NOTE 2)
CJ
Typical thermal resistance (NOTE 3)
Operating junction and storage temperature range
RθJA
TJ,TSTG
Note:1.Reverse recovery condition IF=0.5A,IR=1.0A,Irr=0.25A
2.Measured at 1MHz and applied reverse voltage of 4.0V D.C.
3.P.C.B. mounted with 0.2x0.2”(5.0x5.0mm) copper pad areas
100 200 400 600
70 140 280 420
100 200 400 600
5.0
150.0
1.0
50
98
1.4
5.0
100.0
47.0
-65 to +150
UF5K UF5M
800 1000
560 700
800 1000
1.7
100
82
UNITS
VOLTS
VOLTS
VOLTS
Amps
Amps
Volts
µA
ns
pF
C/W
C
www.shunyegroup.com.cn