LTUC-455 Datasheet, PDF (5/7 Pages) Shoulder Electronics Limited. – TEMPERATURE COEFFICIENT OF CENTER FREQUENCY SHALL BE DEFINED AS THE AVERAGE OF THE CENTRAL FREQUECY. | |||
|
◁ |
PRIOR TO THE MEASUREMENT. IT SHALL FULFILL THE
SPECIFICATIONS IN TABLE 1.
6-2 MOISTURE
KEEP THE FILTER AT 40â AND 95% RH FOR 96 HOURS.THEN
RELEASE THE FILTER INTO THE ROOM CONDITIONS FOR 1 TO
2 HOURS PRIOR TO THE MEASUREMENT. IT SHALL FULFILL THE
SPECIFICATIONS IN TABLE 1.
6-3 LOW TEMPERATURE EXPOSURE
SUBJECT THE FILTER TO -20â FOR 96 HOURS. THEN RELEASE THE
FILTER INTO THE ROOM CONDITIONS FOR 1 TO 2 HOURS PRIOR TO
THE MEASUREMENT. IT SHALL FULFILL THE SPECIFICATIONS IN
TABLE 1.
6-4 TEMPERATURE CYCLING
SUBJECT THE FILTER TO A LOW TEMPERATURE OF -55â FOR 30
MINUTES. FOLLOWSING BY A HIGH TEMPERATURE OF +85â FOR 30
MINUTES. THEN RELEASE THE FILTER INTO THE ROOM CONDITIONS
FOR 1 TO 2 HOURS PRIOR TO THE MESUREMENT. IT SHALL MEET THE
SPECIFICATIONS IN TABLE 1.
6-5 RESISTANCE TO SOLDER HEAT
DIP THE FILTER TERMINALS NO CLOSER THAN 1.5mm INTO THE
SOLDER BATH AT 270â ±10â FOR 10±1 SEC. THEN RELEASE THE
FILTER INTO THE ROOM CONDITIONS FOR 1 TO 2 HOURS. THE
FILTER SHALL MEET THE SPECIFICATIONS IN TABLE 1.
6-6 MECHANICAL SHOCK
DROP THE FILTER RANDOMLY ONTO THE CONCRETE FLOOR FROM
THE HEIGHT OF 30cm 3 TIMES.THE FILTER SHALL FULFILL THE
SPECIFICATIONS IN TABLE 1.
6-7 VIBRATION
SUBJECT THE FILTER TO THE VIBRATION FOR 1 HOUR EACH IN X,Y
AND Z AXES WITH THE AMPLITUDE OF 1.5 mm AT 10 TO 55 Hz. THE
FILTER SHALL FULFILL THE SPECIFICATIONS IN TABLE 1.
6-8 LEAD FATIGUE
6-8-1 PULLING TEST
WEIGHT ALONG WITH THE DIRECTION OF LEAD WITHOUT AN
SHOCK 3 KG. THE FILTER SHALL SATISFY ALL THE INITIAL
CHARACTERISTICS.
6-8-2 BENDING TEST
LEAD SHALL BE SUBJECT TO WITHSTAND AGAINST 90â
BENDING IN THE DERECTION OF THICKNESS. THIS OPERATION
SHALL BE DONE TOWARD BOTH DIRECTION. THE FILTER
SHALL SHOW NO EVIDENCE OF DAMAGE AND SHALLSATISFY
Http://www.shoulder.cn
Page: 5
SHOULDER ELECTRONICS LIMITED
|
▷ |