●Standard Operating Condition・Design Standard For Application Circuit
Item
Input Rated Voltage
Output Nominal Voltage
Output Nominal Current
Conditions
●Standard Operating Condition・Standard Operating Characteristics (Ta=25℃)
Item
Minimum Input Full Load Output Voltage
Maximum Input Light Load Output Voltage
Over Current Protection
Foldback Current
Vin=90V, IO=2.5A
Vin=132V, IO=0.25A
Vin=132V, VO=10V
Conditions
Figure in ○=Terminal Sign
Short Circuit Vin=132V, RO=0.5Ω
MA4510
Ratings
Unit
AC90~132
V
12
V
2.5
A
Ratings
12.0±0.6
12.0±0.6
MAX 3.8
Nodamage To Any Device,
Automatic Recovery.
Unit
V Fig 1, ① Refer
V Fig 1, ② Refer
A Fig 1, ③ Refer
- Fig 1, ④ Refer
Fig1. Output Voltage/Current
Copyright & Copy;2000 Shindengen Electric Mfg.Co.Ltd