GP2L09 Datasheet, PDF (6/6 Pages) Sharp Electrionic Components – Subminiature, High Sensitivity Photointerrupter
GP2L09/GP2L24/GP2L26
s Precautions for Use
( 1) In order to stabilize power supply line, connect a by-pass capacitor of more than 0.01 µ F bet-
ween Vcc and GND near the device.
( 2) In this product, the PWB is fixed with a resin cover, and cleaning solvent may remain inside
the case; therefore, dip cleaning or ultrasonic cleaning are prohibited.
( 3) Remove dust or stains, using an air blower or a soft cloth moistened in cleaning solvent.
However, do not perform the above cleaning using a soft cloth with cleaning solvent in the
marking portion.
In this case, use only the following type of cleaning solvent used for wiping off:
Ethyl alcohol, Methyl alcohol, Isopropyl alcohol, Freon TE, Freon TF, Diflon solvent S3-E
When the cleaning solvents except for specified materials are used, please consult us.
( 4) As for other general cautions, refer to the chapter “ Precautions for Use ” .