English
Language : 

GP1FMV51TK0F Datasheet, PDF (6/8 Pages) Sharp Electrionic Components – Fiber Optic Transmitter Square connector Compact (without mounting hole) With shutter
GP1FMV51TK0F
■Design and Production Notes
(1) Stabilization of power supply line
Please put a by-pass capacitor (0.1 μF) close to the device at least within 7 mm of the terminal.
Please also put a 4.7 μF capacitor across the power supply line nearby.
(2) Soldering condition
Solder at the condition within the absolute maximum ratings in this sheet. In case of using flow soldering, please make
sure of the conditions of process at the flow equipment. Also, do not use reflow soldering. In case of soldering by hand,
do not contact top of soldering iron to lead terminal directly. (Solder at a position more than 1.6 mm away from the base
of the lead terminal.)
(3) About getting dirt and dust in the connector coupling portion
In case dirt or dust comes into the connector coupling portion, please use a blower to take it off.
Any rigid rod-like object must not be inserted since into the coupling portion.
The internal device might be damaged, resulting deteriorated characteristics.
(4) Cleaning
Do not immerse for cleaning. The solvent would get into the connector coupling portion resulting deteriorated
characteristics. Should it be necessary to remove the flux, please use one of the following solvents only to be applied with
a brush.
Solvent : Isopropyl alcohol, Methyl alcohol
(5) Ground during assembling
The human body and the soldering iron must be grounded against the static breakdown of the device during assembling.
Please avoid touching the device terminals as much as possible before assembling.
(6) Assembly of the device
Please fix this device with soldering the metal sheet in PCB. And do not lay the PCB pattern or land for wiring where the
metal sheet contacts PCB.
(7) Input signal
This product is designed intentionally based upon the signal transmission which is defined by the digital audio interface
standard ; CP1201. When a signal out of JEITA standard CP-1201 is inputted to this device, there might be a case that this
device can not transmit a signal correctly to receiving unit.
(8) Fixing pin
Since there are other products which has a different fixing pin shape, please make sure to confirm reference mounting
drawing for this device.
(9) Damage to connector coupling portion
Please do not stress the connector coupling portion excessively since there might be a case that the shutter can’t operate
normally.
(10) About getting the flux into connector coupling portion
Please avoid getting a flux into connector coupling portion of this device, because there might be a case that the characteristics
deteriorate the shutter can’t operate normally.
Sheet No.: E2-A00201EN
6