English
Language : 

GP1UX31QS Datasheet, PDF (5/5 Pages) Sharp Electrionic Components – Holder-less Type IR Detecting Unit for Remote Control
GP1UX31QS Series
9. There is a possibility that noise on output may be caused by environmental condition (Disturbing light noise, Electromagnetic
noise, Power supply line noise, etc.) even if there is no input transmission signal.
10. Please shall confirm operation or your actual machine. Because the output pulse width of this product is fluctuated by
environmental conditions such as signal format, temperature, distance from transmitter, and so on.
11. In case that this product is kept in high humidity condition, it may be hard to solder, please be careful enough about storage
method.
Depend on the flux you select, there are different solderabilities, so please select a suitable flux and use it.
12. This product dose`t correspond to soldering by reflow.
13. Please make sure in case pf hand soldering that yue the solder iron with less than 45W power and solder iron point(edge)
temperature is less than 320 within 3 seconds,and also don't add any force to lead frame directly.And please make sure never
to touch 2nd mold resin by a solding.
14. When using this device,please be careful not to cause dew drop.
Be aware that the dew drop rusts lead pins portion and others, may affect the electric characteristics.
15. The lead flame may be deformed since the device is packed in vinyl bag.
Sheet No.: OP06013
5