GP1F31T/R, GP1F32T/R, GP1F33TT/RR/RT,GP1C331/331A/335
∗10 Jitter measuring method
GP1F31T/GP1F32T/
GP1F33TT/GP1F33RT
Unit to be measured
Vin Vcc GND
Vcc
Standard optical fiber cable
Input
11 0 0
Input signal 3Mbps
biphase mark PBRS signal
CH1
CH2
Standard
receiver
Output
signal
Oscilloscope
Trigger : CH1 Storage mode
Input signal
Standard receiver
output
∆ tj
50%
50%
∆ tj
Note 1 ) The waveform write time shall be 4 seconds. But do
not allow the waveform to be distorted by increasing
the brightness too much.
2 ) VCC = 5.0 ±0.05V (Operating )
3 ) The probe for the oscilloscope must be more than
1MΩ and less than 10pF.
∗11 Maximum input optical power level/Minimum input optical power level measuring method of receiving unit
Standard
transmitter
Variable optical
attenuator
Note 1) Optical power meter must be calibrated to have
the wavelength sensitivity of 660nm.
2) With no optical attenuator connected, use the
transmitter GP1F31T/GP1F32T/GP1F33TT and
the optical fiber cable GP1C331 with the fiber
coupling light output set at - 15dBm/ - 24dBm.
∗12 Dissipation current measuring method
GP1F31R/GP1F32R
GP1F33RR/GP1F33RT
Unit to be measured
Optical power meter
Anritsu : ML93B
Standard
transmitter
Standard optical fiber cable
Vin
Input
Vcc GND VCC = 5.0 ± 0.05V
Vcc
PC= - 15dBm
6Mbps NRZ, duty 50%
or 3Mbps biphase PRBS signal
GP1F31R/GP1F32R
GP1F33RR/GP1F33RT
Unit to be measured
Vcc
GND Vout
Vcc
A
Ammeter
(DC average current value )