English
Language : 

GP1UE27XK Datasheet, PDF (4/7 Pages) Sharp Electrionic Components – Low Voltage Operation, Compact IR Detecting Unit for Remote Control
GP1UE26XK/27XK/28XK/28YK Series
s Performance
Using the transmitter shown in Fig. 1, the output signal of the light detecting unit is good enough to meet the following items in the
standard optical system in Fig. 2.
1. Linear reception distance characteristics
When L=0.2 to 10.0(8.0)*7m, *5EV<10 lx and φ=0˚ in Fig.2, the output signal shall meet the electrical characteristics in the attached list.
2. Sensitivity angle reception distance characteristics
When L=0.2 to 7.5(6.0)*7m, *5EV<10 lx and φ≤30˚ in Fig.2, the output signal shall meet the electrical characteristics in the attached list.
3. Anti outer peripheral light reception distance characteristics
When L=0.2 to 5.0(4.0)*7m, *6EV≤ 300 lx and φ=0˚ in Fig.2, the output signal shall meet the electrical characteristics in the attached list.
*5 It refers to detector face illuminance
*6 Outer peripheral light source: CIE standard light source A shall be used and placed at 45˚ from perpendicular axis at the detector face center
*7 In case of B.P.F. center frequency: 56.8kHz model
Fig.1 Transmitter
20cm
10kΩ
+5V
Transmitter (GL521 used)
f0=(*4)
Duty 50%
VOUT
Oscilloscope
In the above figure, the transmitter should be set so that the output VOUT (P-P) can be 40mV.
However, the PD49PI to be used here should be of the short-circuit current ISC=2.6µA at EV =100 lx.
(EV is an illuminance by CIE standard light source A (tungsten lamp).)
Fig.2 Standard Optical System
Transmitter
Reception distance:L
Light detector face illuminance:EV
φ
φ
VOUT
(φ indicates horizontal and vertical directions.)