English
Language : 

GP1FMV31TK0F Datasheet, PDF (4/8 Pages) Sharp Electrionic Components – Fiber Optic Transmitter Square connector Compact (without mounting hole) With shutter
GP1FMV31TK0F
■Measurement Method
Fig. 1 Output Optical Power Coupled Into Fiber
Standard fiber optic cable
GP1FMV31TK0F
Device under test
Optical power meter
(Anritsu) ML93B
Vin
Vcc
GND
Vcc
The optical power meter must be
calibrated to 660 nm. (0 dBm = 1 mW)
D
Notes
1. Vcc = 3.0 V (State of operating)
2. To bundle up the standard fiber optic cable, make it into a loop with the diameter D = 10 cm or more.
(The standard fiber optic cable will be specified elsewhere.)
Fig. 2 Input Voltage and Supply Current
Standard fiber optic cable
GP1FMV31TK0F
Device under test
Vin
Vcc
GND
Icc
Vin
Vcc
Optical power meter
(Anritsu) ML93B
The optical power meter must be
calibrated to 660 nm. (0 dBm = 1 mW)
Input conditions and judgment method
VCC = 5.0 V (State of operating)
No. Input conditions
1 Vin = 2.9 V or more
2 Vin = 1.3 V or less
Judgment method
-21 ≤ PC ≤ -15 dBm, ICC = 13 mA or less
PC ≤ -36 dBm, ICC = 13 mA or less
VCC = 3.0 V (State of operating)
No. Input conditions
1 Vin = 2.3 V or more
2 Vin = 0.8 V or less
Judgment method
-21 ≤ PC ≤ -15 dBm, ICC = 13 mA or less
PC ≤ -36 dBm, ICC = 13 mA or less
Sheet No.: E2-A00101EN
4