English
Language : 

GP1A74A Datasheet, PDF (4/4 Pages) Sharp Electrionic Components – Compact OPIC Photointerrupter with Connector
GP1A74A/GP1A74A1
(Precautions for Operation)
1) In this product, the PWB is fixed with a hook, and cleaning solvent may remain inside the case;
therefore, dip cleaning or ultrasonic cleaning are prohibited.
2) Remove dust or stains, using an air blower or a soft cloth moistened in cleaning solvent.
However, do not perform the above cleaning using a soft cloth with solvent in the marking portion.
In this case, use only the following type of cleaning solvent for wiping off;
Ethyl alcohol, Methyl alcohol, Isopropyl alcohol,
When the cleaning solvents except for specified materials are used, please contact us.
3) In order to stabilize power supply line, connect a by-pass capacitor of more than 0.01µF between VCC and GND
near the device.
q As for other general precautions, please refer to the chapter "Precautions for Use".