English
Language : 

GP1A38L5 Datasheet, PDF (4/4 Pages) Sharp Electrionic Components – Multi-channel OPIC Photointerrupter with Connector
Fig.6-a Detecting Position Characteristics (2)
(GP1A38L5 )
Output OFF
V CC= 5V, R L= 47kΩ
T a= 25˚C
Detecting position
h=
3.0
+
-
21..05mm
Shield
h
Output ON
0
1
2
3
4
5
6
Shield distance h ( mm)
GP1A38L5/GP1A38L7
Fig.6-b Detecting Position Characteristics (2)
(GP1A38L7 )
VCC= 5V, R L= 47kΩ
T a= 25˚C
Detecting position
h=
3.0
+
-
21..05mm
Shield
h
Output OFF
Output ON
0
1
2
3
4
5
6
Shield distance h ( mm)
s Precautions for Use
( 1) In this product, the PWB is fixed with a resin cover, and cleaning solvent may remain
inside the case; therefore, dip cleaning or ultrasonic cleaning are prohibited.
( 2) Remove dust or stains, using an air blower or a soft cloth moistened in cleaning solvent.
However, do not perform the above cleaning using a soft cloth with cleaning solvent in the
marking portion.
In this case, use only the following type of cleaning solvent used for wiping off:
Ethyl alcohol, Methyl alcohol, Isopropyl alcohol
When the cleaning solvents except for specified materials are used, please consult us.
( 3) In order to stabilize power supply line, connect a by-pass capacitor of more than 0.01µF
between Vcc and GND near the device.
( 4) As for other general cautions, refer to the chapter “ Precautions for Use ”.