English
Language : 

RJ21P3AA0PT Datasheet, PDF (3/18 Pages) Sharp Electrionic Components – 1/1.8-type Interline Color CCD Area Sensor with 3 370 k Pixels
RJ21P3AA0PT
RECOMMENDED OPERATING CONDITIONS
PARAMETER
SYMBOL
MIN. TYP. MAX. UNIT NOTE
Ambient operating temperature
TOPR
25.0
˚C
Output transistor drain voltage
VOD
14.55 15.0 15.45 V
Overflow drain clock p-p level
VØOFD
20.7 21.5 22.8 V
1
Ground
GND
0.0
V
P-well voltage
VPW
–8.0
VØVL
V
2
LOW level
VØV1AL, VØV1BL, VØV2L
–7.35 –7.0 –6.65 V
VØV3AL, VØV3BL, VØV4L
Vertical shift
VØV1AI, VØV1BI, VØV2I
INTERMEDIATE level
0.0
V
register clock
VØV3AI, VØV3BI, VØV4I
HIGH level
VØV1AH, VØV1BH
VØV3AH, VØV3BH
14.55 15.0 15.45 V
Horizontal shift LOW level
VØH1L, VØH2L
–0.05 0.0 +0.05 V
register clock HIGH level
VØH1H, VØH2H
4.5 4.8 5.5
V
Reset gate clock p-p level
VØRS
4.5 4.8 5.5
V
1
Vertical shift register clock frequency
fØV1A, fØV1B, fØV2
fØV3A, fØV3B, fØV4
7.50
kHz
Horizontal shift register clock frequency
fØH1, fØH2
18.00
MHz
Reset gate clock frequency
fØRS
18.00
MHz
NOTES :
1. Use the circuit parameter indicated in "SYSTEM CONFIGURATION EXAMPLE", and do not connect to DC voltage directly.
2. VPW is set below VØVL that is low level of vertical shift register clock, or is used with the same power supply that is connected
to VL of V driver IC.
* To apply power, first connect GND and then turn on VOD. After turning on VOD, turn on VPW first and then turn on other
powers and pulses. Do not connect the device to or disconnect it from the plug socket while power is being applied.
3