RJ21P3AA0PT Datasheet, PDF (3/18 Pages) Sharp Electrionic Components – 1/1.8-type Interline Color CCD Area Sensor with 3 370 k Pixels | |||
|
◁ |
RJ21P3AA0PT
RECOMMENDED OPERATING CONDITIONS
PARAMETER
SYMBOL
MIN. TYP. MAX. UNIT NOTE
Ambient operating temperature
TOPR
25.0
ËC
Output transistor drain voltage
VOD
14.55 15.0 15.45 V
Overflow drain clock p-p level
VÃOFD
20.7 21.5 22.8 V
1
Ground
GND
0.0
V
P-well voltage
VPW
â8.0
VÃVL
V
2
LOW level
VÃV1AL, VÃV1BL, VÃV2L
â7.35 â7.0 â6.65 V
VÃV3AL, VÃV3BL, VÃV4L
Vertical shift
VÃV1AI, VÃV1BI, VÃV2I
INTERMEDIATE level
0.0
V
register clock
VÃV3AI, VÃV3BI, VÃV4I
HIGH level
VÃV1AH, VÃV1BH
VÃV3AH, VÃV3BH
14.55 15.0 15.45 V
Horizontal shift LOW level
VÃH1L, VÃH2L
â0.05 0.0 +0.05 V
register clock HIGH level
VÃH1H, VÃH2H
4.5 4.8 5.5
V
Reset gate clock p-p level
VÃRS
4.5 4.8 5.5
V
1
Vertical shift register clock frequency
fÃV1A, fÃV1B, fÃV2
fÃV3A, fÃV3B, fÃV4
7.50
kHz
Horizontal shift register clock frequency
fÃH1, fÃH2
18.00
MHz
Reset gate clock frequency
fÃRS
18.00
MHz
NOTES :
1. Use the circuit parameter indicated in "SYSTEM CONFIGURATION EXAMPLE", and do not connect to DC voltage directly.
2. VPW is set below VÃVL that is low level of vertical shift register clock, or is used with the same power supply that is connected
to VL of V driver IC.
* To apply power, first connect GND and then turn on VOD. After turning on VOD, turn on VPW first and then turn on other
powers and pulses. Do not connect the device to or disconnect it from the plug socket while power is being applied.