English
Language : 

GP2Y0D413K0F Datasheet, PDF (3/9 Pages) Sharp Electrionic Components – Distance Measuring Sensor Unit Digital output (13 cm) type
■Absolute Maximum Ratings
Parameter
Supply voltage
Output terminal voltage
Operating temperature
Storage temperature
Symbol
VCC
VO
Topr
Tstg
(Ta=25℃,VCC=5V)
Rating
Unit
-0.3 to +7
V
-0.3 to VCC+0.3 V
-10 to +60 ℃
-40 to +70 ℃
GP2Y0D413K0F
■Electro-optical Characteristics
(Ta=25℃,VCC=5V)
Parameter
Average supply current
Detecting distance range
Output voltage
Detecting distance
Symbol
ICC
ΔL
VOH
VOL
L
Conditions
(Note 1)(Note 3)
Output voltage at high level(Note 1)
Output voltage at low level(Note 1)
(Note 1)(Note 2)(Note 4)
MIN. TYP. MAX. Unit
―
14
27 mA
3
―
― cm
VCC-0.3 ―
―
V
―
― 0.6
V
11.5 13 14.5 cm
* L : Distance to reflective object
(Note 1) Using reflective object : White paper (Made by Kodak Co., Ltd. gray cards R-27·white face, reflectance; 90%)
(Note 2) The individual product shall be adjusted to have L = 13 cm ± 1.5 cm as the distance before shipping detecting.
(Note 3) Possible distance measuring range (of the sensor optics)
(Note 4) Output voltage switch has a hysteresis width. The distance specified by L should be
the distance which the output turns from L to H in case an object moves to the sensor.
■Recommended operating conditions
Parameter
Supply voltage
Symbol Conditions Rating Unit
VCC
4.5 to 5.5 V
Sheet No.: E4-A00901EN
3