GP2Y0A710K0F Datasheet, PDF (3/9 Pages) Sharp Electrionic Components – Distance Measuring Sensor Unit Measuring distance: 100 to 550 cm Analog output type
■Absolute Maximum Ratings
Parameter
Supply voltage
Output terminal voltage
Operating temperature
Storage temperature
Symbol
VCC
VO
Topr
Tstg
(Ta=25℃,VCC=5V)
Rating
Unit
-0.3 to +7
V
-0.3 to VCC+0.3 V
-10 to +60 ℃
-40 to +70 ℃
GP2Y0A710K0F
■Electro-optical Characteristics
Parameter
Symbol
Conditions
Average supply current
ICC
L=150cm (Note 1)
Distance measuring
ΔL
(Note 1)
Output voltage
VO
L=100cm (Note 1)
Output voltage differential
ΔVO1
ΔVO2
Output voltage difference between
L=100cm and L=200cm (Note 1)
Output voltage difference (L=100cm→200cm)/
Output voltage differentce (L=200cm→550cm)(Note 1,2)
MIN.
―
100
2.3
0.5
1.25
(Ta=25℃,VCC=5V)
TYP. MAX. Unit
30 50 mA
― 550 cm
2.5 2.7 V
0.7 0.9 V
1.55 1.85 V
* L : Distance to reflective object
Note 1 : Using reflective object : White paper (Made by Kodak Co., Ltd. gray cards R-27・white face, reflectance; 90%)
Note 2 : The value at 550 cm is the average of 20 times distance measuring.
■Recommended operating conditions
Parameter
Supply voltage
Symbol Conditions Rating Unit
VCC
4.5 to 5.5 V
Sheet No.: E4-A00301EN