6-5-5 COM Inversion
There are two types of inputs, COM signal serial input (EXTMODE=âLâ) and external COM signal input (EXTMODE=âHâ).
EXTMODE=âLâ
SCS
SI
COM
M0 M1 M2
â»1
M0 M1 M2
â»1
fCOM
â»2
M0 M1 M2
â»1
â»2
M1ï¼LC polarity inversion flag: If M1is "H" then VCOM="H" is output. If M1 is "L" then VCOM="L" is output.
* 1ï¼LC inversion has been changed by M1 flag statement.
* 2ï¼The periods of plus polarity and minus polarity should be same length as much as possible.
EXTMODE=âHâ
SCS
EXTCOMIN
COM
fEXTCOMIN
â»1
â»2
twEXTCOMINH
â»1
fCOM
â»1
â»2
â»1ï¼LC inversion polarity has been set by the rising timing of EXTCOMIN in internal circuit block as COMZ signal,
â»2ï¼The period of EXTCOMIN should be constant.
â¡ EXTCOMIN input when the SCS signals is low.
SCS
EXTCOMIN
fEXTCOMIN
twEXTCOMINH
COM
â»3
â»4
â»3
fCOM
â»4
â»3ï¼LC inversion polarity has been set by the rising edge of EXTCOMIN.