English
Language : 

LS027B4DH01 Datasheet, PDF (20/29 Pages) Sharp Electrionic Components – Technical Literature For TFT-LCD Module
SPEC No.
MODEL No.
LCY-12T09602C
LS027B4DH01
PAGE
18
6-5-5 COM Inversion
There are two types of inputs, COM signal serial input (EXTMODE=”L”) and external COM signal input (EXTMODE=”H”).
EXTMODE=“L”
SCS
SI
COM
M0 M1 M2
※1
M0 M1 M2
※1
fCOM
※2
M0 M1 M2
※1
※2
M1:LC polarity inversion flag: If M1is "H" then VCOM="H" is output. If M1 is "L" then VCOM="L" is output.
* 1:LC inversion has been changed by M1 flag statement.
* 2:The periods of plus polarity and minus polarity should be same length as much as possible.
EXTMODE=“H”
SCS
EXTCOMIN
COM
fEXTCOMIN
※1
※2
twEXTCOMINH
※1
fCOM
※1
※2
※1:LC inversion polarity has been set by the rising timing of EXTCOMIN in internal circuit block as COMZ signal,
※2:The period of EXTCOMIN should be constant.
② EXTCOMIN input when the SCS signals is low.
SCS
EXTCOMIN
fEXTCOMIN
twEXTCOMINH
COM
※3
※4
※3
fCOM
※4
※3:LC inversion polarity has been set by the rising edge of EXTCOMIN.
※4:The period of EXTCOMIN should be constant.