English
Language : 

GP2Y0D340K Datasheet, PDF (2/4 Pages) Sharp Electrionic Components – Compact Distance Measuring Sensors
s Electro-optical Characteristics
Parameter
Symbol
Conditions
MIN. TYP.
Distance measuring range
∆L
*1 *3
10
−
Output terminal voltage
VOH
VOL
Distance characteristics of output VO
Output voltage at High *1
Output voltage at Low*1
*1 *4 *2
VCC −0.3
−
−
−
35
40
Average dissipation current
ICC
at R1=1Ω
−
28
Note) L : Distance to reflective object
*1 Using reflective object : White paper (Made by Kodak Co. Ltd. gray cards R-27 ⋅ white face, reflective ratio;90%)
*2 We ship the device after the following adjustment : Output switching distance L=40cm±5cm must be measured by the sensor
*3 Distance measuring range of the optical sensor system
*4 Output switching has a hysteresis width. The distance specified by Vo should be the one with which the output L switches to the output H
GP2Y0D340K
(Ta=25˚C, VCC=5V)
MAX. Unit
60
cm
−
V
0.6
V
45
cm
35
mA
Fig.1 Internal Block Diagram
GND
VCC
PSD
Signal
processing
circuit
Voltage
regulator
Oscillation
circuit
LED drive
circuit
LED
Output
circuit
Distance measuring IC
C1=(1µF)
R1=1Ω (LED current TYP. 300mA)
REG
C1
VO
R1
LED_FB
Fig.2 Timing Chart
VCC
(Power supply)
TYP. 3.2ms TYP. 6.4ms
TYP. 6.4ms
Distance
measuring
operation
First measurment Second measurment
Stand by period
nth
measurment
VO (Output)
Unstable output
First output
Second output
nth output