English
Language : 

GP2D12 Datasheet, PDF (2/4 Pages) Sharp Electrionic Components – General Purpose Type Distance Measuring Sensors
GP2D12/GP2D15
s Recommended Operating Conditions
Parameter
Symbol Rating Unit
Operating supply voltage
VCC 4.5 to +5.5 V
s Electro-optical Characteristics
Parameter
Distance measuring range
GP2D12
Output terminal voltage GP2D15
Difference of output voltage GP2D12
Distance characteristics of output GP2D15
Average Dissipation current
Symbol
∆L
VO
VOH
VOL
∆VO
VO
ICC
Conditions
*1 *3
L=80cm *1
Output voltage at High *1
Output voltage at Low *1
Output change at L=80cm to 10cm *1
*1 *2 *4
L=80cm *1
MIN.
10
0.25
Vcc −0.3
−
1.75
21
−
TYP.
−
0.4
−
−
2.0
24
33
Note) L : Distance to reflective object.
*1 Using reflective object : White paper (Made by Kodak Co. Ltd. gray cards R-27 ⋅ white face, reflective ratio ; 90%).
*2 We ship the device after the following adjustment : Output switching distance L=24cm±3cm must be measured by the sensor.
*3 Distance measuring range of the optical sensor system.
*4 Output switching has a hysteresis width. The distance specified by Vo should be the one with which the output L switches to the output H.
(Ta=25°C, VCC=5V)
MAX. Unit
80
cm
0.55
V
−
V
0.6
V
2.25
V
27
cm
50
mA
Fig.1 Internal Block Diagram
GP2D12
GND
VCC 5V
PSD
LED
Signal
processing
circuit
LED drive
circuit
Voltage
regulator
Oscillation
circuit
Output
circuit
Distance measuring IC
Vo
Analog output
Fig.2 Internal Block Diagram
GP2D15
GND
VCC 5V
PSD
LED
Signal
processing
circuit
LED drive
circuit
Voltage
regulator
Oscillation
circuit
Output
circuit
Distance measuring IC
VCC
12kΩ
Vo
Digital output
Fig.3 Timing Chart
VCC
(Power supply)
Distance
measuring
operation
VO (Output)
38.3ms±9.6ms
First measurment
Unstable output
Second
measurment
nth
measurment
First output
Second output
5.0msMAX.(GP2D12)
7.6ms±1.9msTYP.(GP2D15)
nth output