12. Handling of modules
12-1. Connecting the FPC by the ACF
1) Be sure to turn off the power supply and the signals when connecting the FPC
2) Please connect for too much stress not to join FPC in the case of connection of FPC.
12-2. About handling of FPC
1) Do not dangle the LCD module by holding the FPC, or do not give any stress to it.
11-3. Mounting of the module
1) The module should be held on to the plain surface. Do not give any warping or twisting stress to the
module.
11-4. Cautions in assembly / Handling pre cautions
As the polarizer can be easily scratched, be most careful in handling it.
1) Work environments in assembly.
Working under the following environments is desirable:
a) Implement more than 1MΩ conductive treatment (by placing a conductive mat or applying
conductive paint) on the floor or tiles.
b) No dusts come in to the working room. Place an adhesive, anti-dust mat at the entrance of the room.
c) Humidity of 50 to 70% and temperature of 15 to 27°C are desirable.
d) All workers wear conductive shoes, conductive clothes, conductive fingerstalls and grounding belts
without fail.
e) Use a blower for electrostatic removal. Set it in a direction slightly tilt downward so that each Module
can be well subjected to its wind. Set the blower at an optimum distance between the blower and the
module.
2) How the remove dust on the polarizer
a) Blow out dust by the use of an N² blower with antistatic measures taken. Use of an ionized air gun
is recommendable.
b) When the panel surface is soiled, wipe it with soft cloth.
3) If water dropped, etc. remains stuck on the polarizer for a long time, it is apt to get discolored or cause
stains. Wipe it immediately.
4) As a glass substrate is used for the TFT-LCD panel, if it is dropped on the floor or hit by something
hard, it may be broken or chipped off.
5) Since CMOS LSI is used in this module, take care of static electricity and take the human earth into
consideration when handling.
12-5. Others
1) If stored at temperatures below the rated values, the inner liquid crystal may freeze, causing cell
destruction. At temperatures exceeding the rated values for storage, the liquid crystal may become
isotropic liquid, making it no longer possible to come back to its original state in some cases.
2) If the LCD is broken, do not drink liquid crystal in the mouth. If the liquid crystal adheres to a hand or
foot or to clothes, immediately cleanse it with soap.
3) If a water drop or dust adheres to the polarizer, it is apt to cause deterioration. Wipe it immediately.
4) Be sure to observe other caution items for ordinary electronic parts and components.
5) Epoxy resin (amine series curing agent), silicone adhesive material (dealcoholization series and
oxime series), tray forming agent (azo compound) etc, in the cabinet or the packing materials may
induce abnormal display with polarizer film deterioration regardless of contact or noncontact to
polarizer film.
Be sure to confirm the component of them.