LQ201U1LW01 Datasheet, PDF (13/26 Pages) Sharp Electrionic Components – TFT-LCD Module | |||
|
◁ |
LD-14115-10
6-2. Back light driving
The back light system is an edge-lighting type with six CCFTs (Cold Cathode Fluorescent Tube).
The characteristics of the lamp are shown in the following table.
The value mentioned below is at the case of one CCFT.
CCFT Model Nameï¼KTBE26MSTFâA424NE209âZâ3ï¼STANLEY.ELECTRIC.CO.,LTDï¼
Parameter
Symbol Min. Typ. Max. Unit
Remark
Lamp current range
IL
3.0
6.0
6.5 mArms ãNote1ã
Lamp voltage
VL
ï¼
790
ï¼ Vrms Ta=25â
Lamp power consumption
PL
ï¼
4.7
ï¼
W ãNote2ã
Lamp frequency
FL
30
60
70 KHz ãNote3ã
Kick-off voltage
Vs
ï¼
ï¼ 1,500 Vrms Ta=25âãNote4ã
ï¼
ï¼ 2,000 Vrms Ta=0âãNote4ã
Lamp life time
TL 50,000 ï¼
ï¼ Hour ãNote5ã
ãNote1ã A lamp can be light in the range of lamp current shown above.
Maximum rating for current is measured by high frequency current measurement equipment
connected to VLOW at circuit showed below.
(Note : To keep enough kick-off voltage and necessary steady voltage for CCFT.)
Lamp frequency : 30ï½70kHz
Ambient temperature : 0ï½50â
Module
CN1:1,2,3,4,5,6:
1pin(Vhigh)
CN1:1,2,3,4,5,6:
A
2pin(Vlow)
ï½
Inverter
ãNote2ã Referential data per one CCFT by calculation ( IL Ã VL ) .
The data doesnât include loss at inverter .
ãNote3ã Lamp frequency of inverter may produce interference with horizontal synchronous frequency, and
this may cause horizontal beat on the display. Therefore, adjust lamp frequency, and keep inverter as far
as from module or use electronic shielding between inverter and module to avoid interference.
ãNote4ãKick-off voltage value is described as the index in the state of lamp only.
The kick-off voltage is estimated to be risen up as approx. +200V in the state of module only, and the
further rise up can be seen according to the assembling status of user cabinet.ãPlease set the kick-off
voltage of inverter to avoid the lighting failures in the state of operation. Please design the inverter so
that its open output voltage can be connected for more than 1 second to startup. Otherwise, the lamp
may not be turned on. But, please set as 100ms when the ambient luminance around the lamp is more
than 1lux.
ãNote5ã Lamp life time is defined as the time when either â or â¡ occurs in the continuous operation under
the condition of Ta=25â and IL=6.0 mArms .
â Brightness becomes 50% of the original value under standard condition.
â¡ Kick-off voltage at Ta=0â exceeds maximum value,2000Vrms .
ãNoteã
The performance of the backlight, for example lifetime or brightness, is much influenced by the characteristics
of the DC-AC inverter for the lamp. When you design or order the inverter, please make sure that a poor lighting
caused by the mismatch of the backlight and the inverter (miss-lighting, flicker, etc.) never occurs. When you
confirm it, the module should be operated in the same condition as it is installed in your instrument.
Use the lamp inverter power source incorporating such safeguard as overvoltage / overcurrent protective circuit
or lamp voltage waveform detection circuit, which should have individual control of each lamp.
In case one circuit without such individual control is connected to more than two lamps, excessive current may
flow into one lamp when the other one is not in operation.
Synchronize frequency and phase of two CCFT in the same connector.
Otherwise it may exceed rated voltage of connector.
|
▷ |