English
Language : 

S11ME5 Datasheet, PDF (1/4 Pages) Sharp Electrionic Components – Phototriac Coupler Conformable to European Safety Standard
S11ME5/S11ME6/S21ME5/S21ME5F/S21ME6/S21ME6F
S11ME5/S11ME6/S21ME5F
S21ME5/S21ME6/S21ME6F
Phototriac Coupler Conformable to
European Safety Standard
g Lead forming type ( I type) of / S21ME5F/ S21ME6F are also available. (/ S21ME5FI/ S21ME6FI)
g DIN-VDE0884 approved type is also available as an option.
s Features
s Outline Dimensions
(Unit : mm)
1. Internal isolation distance : 0.4mm or more
2. Creepage distance : 6.4mm or more
S11ME5/S11ME6
S21ME5/S21ME6
S21ME5F/S21ME6F
3. Clearance : 6.4mm or more
4. Recogized by UL file No. E64380
Approved by VDE (DIN-VDE0884 : No.76850)
Approved by BSI (BS415 : No.6690, BS7002 : No.7421)
Approved by SEMKO (No.9202227)
Approved by DEMKO (No.107968 )
Approved by EI (No.152029-02,03,04,0116 )
Anode mark
S11ME5
6.5± 0.5
7.62± 0.3
4.58± 0.5
Anode mark
1
4
S21ME5
2
3
6.5± 0.5
7.62± 0.3
4.58± 0.5
5. Built-in zero-cross circuit
(S11ME6/S21ME6/S21ME6F )
6. Wide forming type (S21ME5F, S21ME6F)
( Distance between lead pins : 10.16 mm)
7. High isolation voltage between input and
0.26± 0.1
θ θ : 0 to 13˚
0.5± 0.1
0.26± 0.1
10.16± 0.5
0.5±0.1
output
( Viso : 5 000Vrms )
Internal connection diagram
S11ME5/S21ME5/S21ME5F
4
3
S11ME6/S21ME6/S21ME6F
4
3
s Applications
1. For triggering medium/high power triac
2. For detecting over voltage of switching
power supply
1
2
1 Anode
2 Cathode
3 Anode/
Cathode
1
4 Anode/
Cathode
2
Zero-cross circuit
s Absolute Maximum Ratings
Input
Output
Parameter
Forward current
Reverse voltage
RMS ON-state current
∗1 Peak one cycle surge current
Repetitive peak
S11ME5 / S11ME6
OFF-state voltage ∗2S21ME5 /S21ME6
∗3 Isolation voltage
Operating temperature
Storage temperature
∗4 Soldering temperature
∗1 50Hz sine wave ∗2 Also S21ME5F/ S21ME6F
∗3 40 to 60% RH, AC for 1 minute, f = 60Hz
∗4 For 10 seconds
Symbol
IF
VR
IT
Isurge
V DRM
Viso
Topr
Tstg
Tsol
( Ta = 25˚C)
Rating
50
6
100
1.2
400
600
5 000
- 30 to + 100
- 55 to + 125
260
Unit
mA
V
mArms
A
V
V rms
˚C
˚C
˚C
“ In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that occur in equipment using any of SHARP's devices, shown in catalogs,
data books, etc. Contact SHARP in order to obtain the latest version of the device specification sheets before using any SHARP's device.”