PQ1CG41H2FZ Datasheet, PDF (1/4 Pages) Sharp Electrionic Components – TO-220 Type Chopper Regulator built-in 300kHz oscillation circuit | |||
|
Chopper Regulators
PQ1CG41H2FZ/PQ1CG41H2RZ
PQ1CG41H2FZ/PQ1CG41H2RZ
TO-220 Type Chopper Regulator built-in 300kHz oscillation circuit
I Features
G Maximum switching current: 1.5A
G Built-in ON/OFF control function
G Built-in soft start function to suppress overshoot of output
voltage in power on sequence or ON/OFF control sequence
G Built-in oscillation circuit
(Oscillation frequency: TYP. 300kHz)
G Built-in overheat, overcurrent protection functions
G TO-220 package
G Variable output voltage
(Output variable range: Vref to 35V/-Vref to -30V)
[Possible to select step-down output/inversing output
according to external connection circuit]
G PQ1CG41H2FZ: Zigzag forming
PQ1CG41H2RZ: Self-stand forming
I Applications
G CTV, CTB
G LCD monitors
G Facsimiles, printers and other OA equipment
G CD-ROM drives/DVD-ROM drives
I Absolute Maximum Ratings
(Ta=25°C)
Parameter
Symbol Rating
Unit
â1 Input voltage
VIN
40
V
Error input voltage
Vadj
7
V
Input-output voltage
VI-O
41
V
â2 Output â COM voltage VOUT
â1
V
â3 ON/OFF control voltage VC â0.3 to +40 V
Switching current
ISW
1.5
A
â4 Power dissipation
â5 Junction temperature
Operating temperature
Storage temperature
PD1
1.4
W
PD2
14
W
Tj
150
ËC
Topr â20 to +80
ËC
Tstg â40 to +150 ËC
Soldering temperature
Tsol
260 (10s)
ËC
â1 Voltage between VIN terminal and COM terminal
â2 Voltage between VOUT terminal and COM terminal
â3 Voltage between ON/OFF control and COM terminal
â4 PD:With infinite heat sink
â5 Overheat protection may operate at the condition Tj:125ËC to 150ËC.
I Outline Dimensions
PQ1CG41H2FZ10.2MAX.
(6.8)
(Unit : mm)
4.5±0.2
2.8±0.2
ø3.2±0.1
PQ1CG41H
Epoxy resin
(0.5)
5â0.8±0.1
(1.5)
4â(1.7)
12345
( ) : Typical dimensions
PQ1CG41H2RZ
10.2MAX.
(6.8)
(5.0)
8.2±0.7
3.2±0.5
1 VIN
2 VOUT
3 COM
4 Oadj
5 ON/OFF control
4.5±0.2
2.8±0.2
ø3.2±0.1
PQ1CG41H
Epoxy resin
0.8±0.1
4â(1.7)
(1.7)
(0.5)
4.7±0.6 4.7±0.6
2.6±0.5
12345
(
1 VIN
2 VOUT
3 COM
4 Oadj
5 ON/OFF control
) : Typical dimensions
â¢Please refer to the chapter " Handling Precautions ".
Notice In the absence of confirmation by device specification sheets,SHARP takes no responsibility for any defects that may occur in equipment using any SHARP
devices shown in catalogs,data books,etc.Contact SHARP in order to obtain the latest device specification sheets before using any SHARP device.
Internet Internet address for Electronic Components Group http://sharp-world.com/ecg/
|
▷ |