PC924 Datasheet, PDF (1/6 Pages) Sharp Electrionic Components – OPIC Photocoupler for IGBT Drive of Inverter
PC924
PC924
OPIC Photocoupler for IGBT
Drive of Inverter
g Lead forming type ( I type ) and taping reel type ( P type ) are also available. ( PC924I/PC924P)
gg TÜV ( VDE 0884 ) approved type is also available as an option.
s Features
s Outline Dimensions
(Unit : mm )
1. Built-in direct drive circuit for IGBT drive
( IO1P , I O2P : 0.4A)
2. High speed response ( tPLH , t : PHL MAX. 2.0 µ s )
3. Wide operating supply voltage range
( VCC : 15 to 30V at Ta = - 10 to 60˚C )
4. High noise resistance type
CM H : MIN. - 1 500V/ µs
CM L : MIN. 1 500V/ µs
5. High isolation voltage ( Viso : 5 000V rms )
s Applications
Anode
mark
2.54 ± 0.25
8765
Internal connection diagram
8765
PC924
123 4
0.85 ± 0.2
1.2 ± 0.3
Tr1
Interface
1234
Tr2
Amp.
9.66 ± 0.5
7.62 ± 0.3
1. IGBT drive for inverter control
0.5
0.26 ± 0.1
θ
θ = 0 to 13 ˚
1 Anode
2 Cathode
3 NC
4 NC
5 O1
6 O2
7 GND
8 VCC
* “ OPIC ” ( Optical IC ) is a trademark of the SHARP Corporation.
An OPIC consists of a light-detecting element and signal-
processing circuit integrated onto a single chip.
s Absolute Maximum Ratings
Input
Output
Parameter
Forward current
Reverse voltage
Supply voltage
O1 output current
*1O1 peak output current
O2 output current
*1O2 peak output current
O1 output voltage
Power dissipation
Total power dissipation
*2 Isolation voltage
Operating temperature
Storage temperature
*3Soldering temperature
(Unless specified, Ta = T opr)
Symbol
IF
VR
V CC
IO1
I O1P
IO2
I O2P
V O1
PO
P tot
V iso
T opr
T stg
T sol
Rating
25
6
35
0.1
0.4
0.1
0.4
35
500
550
5 000
- 25 to + 80
- 55 to + 125
260
Unit
mA
V
V
A
A
A
A
V
mW
mW
V rms
˚C
˚C
˚C
*1 Pulse width<= 0.15 µ s,
Duty ratio : 0.01
*2 40 to 60% RH, AC for
1 minute, Ta = 25˚C
*3 For 10 seconds
“ In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that occur in equipment using any of SHARP's devices, shown in catalogs,
data books, etc. Contact SHARP in order to obtain the latest version of the device specification sheets before using any SHARP's device.”