English
Language : 

PC852 Datasheet, PDF (1/5 Pages) Sharp Electrionic Components – High Collector-emitter Voltage Type Photocouplers
PC852 Series/PC853/PC853H
PC852 Series
PC853/PC853H
High Collector-emitter Voltage
Type Photocouplers
g Lead forming type ( I type ) and taping reel type ( P type ) are also available. ( PC852I/PC852P/PC853I/PC853P )
s Features
PC8D52 (2-channel type )
1. High collector-emitter voltage
PC8Q52 (4-channel type )
PC852 Series , PC853 ( VCEO : 300V)
PC853H ( VCEO : 350V)
2. High current transfer ratio
( CTR: MIN. 1 000% at IF = 1mA, V CE = 2V)
5. Large collector power dissipation.
PC853 , PC853H (PC : 300mW )
6. Recognized by UL ( NO. E64380 )
s Applications
3. High isolation voltage between input and
output ( Viso : 5 000V rms )
1. Telephone sets
2. Copiers, facsimiles
4. Compact dual-in-line package
PC852 , PC853 , PC853H ( 1-channel type )
3. Interface with various power supply cir-
cuits, power distribution boards
s Outline Dimensions
4. Numerical control machines
( Unit : mm)
PC852/PC853/PC853H
2.54 ± 0.25 Model No
43
Internal connection
diagram
43
PC8Q52
Internal connection
diagram
16 15 14 13 12 11 10 9
1 2 0.9 ± 0.2
1.2 ± 0.3
4.58 ± 0.5
12
7.62 ± 0.3
0.5 ± 0.1
1 Anode
2 Cathode
PC8D52
8
2.54± 0.25
7
65
PC8D52
0.26 ± 0.1
θ θ = 0 to 13 ˚ θ
3 Emitter
4 Collector
Internal connection
diagram
8 7 65
1 2 34 56 7 8
2.54 ± 0.25
16 15
14 13 12 11 10 9
PC8Q52
1
2 34 56 7 8
0.9 ± 0.2
1.2 ± 0.3
19.82 ± 0.5
7.62 ± 0.3
1
2 34
0.9 ± 0.2
1.2 ± 0.3
9.66 ± 0.5
1 2 34
7.62 ± 0.3
0.5 ± 0.1
0.26 ± 0.1
θ θ = 0 to 13 ˚ θ
0.26 ± 0.1
0.5 ± 0.1
1 3 Anode
2 4 Cathode
θ θ = 0 to 13 ˚ θ
5 7 Emitter
6 8 Collector
(Note)
1 3 5 7 Anode
2 4 6 8 Cathode
9 11 13 15 Emitter
10 12 14 16 Collector
The diode of output side is not a protection diode
of reverse voltage.
“ In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that occur in equipment using any of SHARP's devices, shown in catalogs,