PC3SG11YIZ Datasheet, PDF (1/13 Pages) Sharp Electrionic Components – Non-zero cross type Mini-Flat Package Phototriac Coupler for triggering
PC3SG11YIZ
Series
∗Zero cross type is also available.
(PC3SG21YIZ Series)
PC3SG11YIZ Series
VDRM : 600V, Reinforced Insulation Type
Non-zero cross type
Mini-Flat Package
Phototriac Coupler for triggering
■ Description
PC3SG11YIZ Series reinforced insulation type
Phototriac Coupler include an infrared emitting diode
(IRED) optically coupled to an output Phototriac.
These devices feature full wave control and are
ideal isolated drivers for medium to high current Triacs.
SOP package provides 3.75kV isolation from input
to output with superior commutative noise immunity.
■ Features
1. High repetitive peak off-state voltage (VDRM : 600V)
2. Non-zero crossing functionality
3. 4 pin Mini-Flat package
4. Reinforced insulation type (MIN. 0.4mm internal
separation)
5. Superior noise immunity (dV/dt : MIN. 100V/µs)
6. Lead-free components are also available (see Model
Line-up section in this datasheet)
7. Double transfer mold construction (Ideal for Flow
Soldering)
8. High isolation voltage between input and output
(Viso(rms) : 3.75kV)
■ Agency approvals/Compliance
1. Recognized by UL1577 (Double protection isolation),
file No. E64380 (as model No. 3SG11)
2. Approved by VDE (∗)(DIN EN 60747-5-2), file No.
40009162 (as model No. 3SG11)
3. Package resin : UL flammability grade (94V-0)
(∗) DIN EN60747-5-2 : successor standard of DIN VDE0884.
Up to Date code "RD" (December 2003), approval of DIN
VDE0884.
From Date code "S1" (January 2004), approval of DIN
EN60747-5-2.
■ Applications
1. Triggering for Triacs used to switch on and off
devices which require AC Loads.
For example heaters, fans, motors, solenoids, and
valves.
2. Triggering for Triacs used for implementing phase
control in applications such as lighting control and
temperature control (HVAC).
3. AC line control in power supply applications.
Notice The content of data sheet is subject to change without prior notice.
In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that may occur in equipment using any SHARP
devices shown in catalogs, data books, etc. Contact SHARP in order to obtain the latest device specification sheets before using any SHARP device.
Sheet No.: D2-A06801EN
1
Date Mar. 31. 2004
© SHARP Corporation