s Features
1. Low input current type (IF=±0.5mA)
2. High resistance to noise due to high common rejection
voltage (CMR:MIN. 10kV/µs)
3. AC input type
4. Mini-flat package PC3H41X NIP Series (1ch)
PC3Q410 NIP (4ch)
5. Isolation voltage (Viso:2.5kVrms)
6. Recognized by UL, file No. E64380
s Applications
1. Programmable controllers
2. Facsimiles
3. Telephones
s Rank Table
Model No. Rank mark
PC3H410NIP A or no mark
PC3H411NIP
A
Model No. Rank mark
PC3Q410NIP No mark
Ic (mA)
0.25 to 2.0
0.5 to 1.5
Ic (mA)
0.25 to 2.0
Conditions
IF=±0.5mA
VCE=5V
Ta=25°C
Conditions
IF=±0.5mA
VCE=5V
Ta=25°C
s Absolute Maximum Ratings
(Ta=25°C)
Parameter
Symbol Rating Unit
Forward current IF
Input *1 Peak forward current IFM
±10
mA
±200
mA
Power dissipation P
15
mW
Collector-emitter voltage VCEO
70
V
Output Emitter-collector voltage VECO
6
V
Collector current IC
50
mA
Collector power dissipation PC
150
mW
Total power dissipation Ptot
170
mW
Operating temperature Topr
Storage temperature Tstg
*2 Isolation voltage Viso
*3 Soldering temperature Tsol
−30 to +100
−40 to +125
2.5
260
°C
°C
kVrms
°C
*1 Pulse width<=100µs, Duty ratio=0.001
*2 40 to 60%RH, AC for 1 minute, f=60Hz
*3 For 10s
AC Input, Low Input Current
Type Photocoupler
s Outline Dimensions
PC3H41xNIP Series
Anode mark
1
4
H41
2
3
4.4±0.2
5.3±0.3
(Unit : mm)
Internal connection
diagram
4
3
1 Anode
(Cathode)
2 Cathode
(Anode)
3 Emitter
4 Collector
1
2
Epoxy resin
7.0−+00..72
0.5−+00..24
PC3Q410NIP
10.3±0.3
1.27±0.25
16
9
Internal connection
diagram
16 15 14 13 12 11 10 9
PC3Q41
1
8 0.4±0.1
Primary side mark
1 23 45 67 8
1 3 5 7 Anode (Cathode)
2 4 6 8 Cathode (Anode)
9 11 13 15 Emitter
10 12 14 16 Collector
Epoxy resin
C0.4
(Input side)
5.3±0.3
6°
0.5−+00..24
7.0−+00..72
0.2mm or more
Soldering area
Notice In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that may occur in equipment using any SHARP
devices shown in catalogs, data books, etc. Contact SHARP in order to obtain the latest device specification sheets before using any SHARP device.
Internet Internet address for Electronic Components Group http://www.sharp.co.jp/ecg/