I Features
1. Isolation voltage between input and output (Viso (rms):5kV)
2. High critical rate of rise of OFF-state voltage
(dV/dt:MIN. 1 000V/µs)
3. Internal isolation distance (0.4mm or more)
4. Recognized by UL (File No. E64380)
Approved by VDE (VDE0884, File No.127413)
Approved by BSI (BS415, File No.6690,
BS7002, File No.7421)
Approved by SEMKO (File No.0033029/01-04)
Approved by DEMKO (File No.310107-01)
Approved by FIMKO (File No.15795)
❈ PC3SF11YVZA, PC3SF11YVZB are for 200V line
I Applications
1. Home appliances
2. OA equipment, FA equipment
3. SSRs
I Model Line-up
Minimum trigger current (IFT[MAX.])
10mA
7mA
for AC 200V line
PC3SF11YVZA
PC3SF11YVZB
I Absolute Maximum Ratings
(Ta=25°C)
Parameter
Symbol Rating Unit
Input *1 Forward current
IF
Reverse voltage VR
50
mA
6
V
*1 RMS ON-state current IT (rms)
0.1
A
Output Peak one cycle surge current Isurge 1.2 (50Hz sine wave) A
Repetitive peak OFF-state voltage VDRM
600
V
*2 Isolation voltage Viso (rms)
5
kV
Operating temperature Topr −30 to +100 °C
Storage temperature Tstg −55 to +125 °C
Soldering temperature Tsol 260 (For 10s) °C
*1 The derating factors of absolute maximum ratings due to ambient temperature are
shown in Fig.1, 2
*2 AC for 1 min, 40 to 60%RH, f=60Hz
Reinforced Insulation Type
Phototriac Coupler for
Triggering
I Outline Dimensions
2.54±0.25
(Unit : mm)
Internal connection
diagram
654
Anode
mark
3SF11
NC
123
123
0.6±0.2
1.2±0.3
7.12±0.3
7.62±0.3
0.5±0.1
10.16±0.5
1 Anode
2 Cathode
3 NC
4 Anode, Cathode
5 No external connection
6 Anode, Cathode
❈ Pin 5 is not allowed external connection
Notice In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that may occur in equipment using any SHARP
devices shown in catalogs, data books, etc. Contact SHARP in order to obtain the latest device specification sheets before using any SHARP device.
Internet Internet address for Electronic Components Group http://sharp-world.com/ecg/