English
Language : 

PC123 Datasheet, PDF (1/4 Pages) Sharp Electrionic Components – European Safety Standard Approved Type Long Creepage Distance Photocoupler
PC123/PC123F
PC123/PC123F
European Safety Standard
Approved Type Long Creepage
Distance Photocoupler
g DIN-VDE0884 approved type ( PC123Y/PC123FY ) is also available as an option.
s Features
1. Conform to European Safety Standard
2. Internal isolation distance : 0.4mm or more
3. High collector-emitter voltage ( VCEO : 70V)
4. Long creepage distance type
5. Recognized by UL (No. E64380)
Approved by VDE ( DIN-VDE83601 )
Approved by BSI
( BS415 No. 7087, BS7002 No. 7409 )
Approved by SEMCO ( No. 9216212 )
Approved by DEMCO ( No. 108954)
Approved by NEMKO ( No. 199438181 )
Approved by EI ( No. 155030)
Recognized by CSA (No. CA95323)
PC123
PC123F
Creepage distance
6.4mm or more
8mm or more
Space distance
6.4mm or more
8mm or more
s Applications
1. Power supplies
2. OA equipment
s Absolute Maximum Ratings (Ta = 25˚C )
Parameter
Forward current
*1Peak forward current
Input
Reverse voltage
Power dissipation
Collector-emitter voltage
Emitter-collector voltage
Output
Collector current
Collector power dissipation
Total power dissipation
*2 Isolation voltage
Operating temperature
Storage temperature
*3 Soldering temperature
Symbol
IF
I FM
VR
P
V CEO
V ECO
IC
PC
P tot
V iso
T opr
T stg
T sol
Ratings
50
1
6
70
70
6
50
150
200
5
- 30 to + 100
- 55 to + 125
260
Unit
mA
A
V
mW
V
V
mA
mW
mW
kV rms
˚C
˚C
˚C
*1 Pulse width <= 100 µ s, Duty ratio : 0.001
*2 AC for 1 minute, 40 to 60% RH
*3 For 10 seconds
s Outline Dimensions
(Unit : mm )
PC123
Anode mark
1
Internal connection diagram
1
2
4
1 Anode
4 2 Cathode
3 3 Emitter
4 Collector
PC123
2 6.5 ± 0.3 3
7.62 ± 0.3
4.58 ± 0.3
PC123F
Epoxy resin
0.26 ± 0.1
Anode mark
1
4
PC123
2 6.5 ± 0.3 3
7.62 ± 0.3
0.5 ± 0.1
Internal connection diagram
1 Anode
1
4 2 Cathode
2
3 3 Emitter
4 Collector
4.58 ± 0.3
Epoxy resin
0.26 ± 0.1
10.16 ± 0.5
0.5 ± 0.1
“ In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that occur in equipment using any of SHARP's devices, shown in catalogs,
data books, etc. Contact SHARP in order to obtain the latest version of the device specification sheets before using any SHARP's device. ”