English
Language : 

LT260A Datasheet, PDF (1/2 Pages) Sharp Electrionic Components – GaAs Hall IC for Noncontact Switch(Alternating magnetic field-type)
Hall IC
LT260A
LT260A
GaAs Hall IC for Noncontact Switch
(Alternating magnetic field-type*)
s Features
*Zero-cross is not warranted.
¡Operation by small magnet due to high sensitivity s Outline Dimensions
(Unit : mm)
Operating point<10mT
¡Combining a GaAs Hall device and an IC in a compact
package (2.9X1.5X1.1mm)
¡Wide operation temperature range obtained by GaAs Hall
2.7±0.3
Y
1
4
device (-20 to +125˚C)
¡Long life time due to noncontact-type
S
Z
s Applications
¡FDD
¡HDD
¡Water meter
¡Car stereo
¡Microswitch,etc.
s Absolute Maximum Ratings
Parameter
Supply voltage
Output voltage
Output current
Power dissipation
Operating temperature
Storage temperature
Soldering temperature* 1
Symbol
VCC
VOUT
IO
PD
Topr
Tstg
Tsol
*1 Soldering time : within 10 seconds
(Ta=25˚C)
Rating Unit
18
V
18
V
5
mA
100
mW
-20 to +125 ˚C
-55 to +150 ˚C
260
˚C
2
3
X
4-R0.2
Hall device center line
X : +0.05±0.23mm against package center
Y : -0.05±0.1mm against package lead center between
No.2 and No.3 terminals
Z : 0.81±0.15mm from package surface
0.6 1.5±0.2 0.6
Terminal connections
REG
Hall
device
H
1 : VCC
2 : VOUT
*No.3 terminal and the section of leads(both sides
of package in X directionÅajre connected with the
3 : Don't use.
4 : GND
terminal of internal IC. Be careful in connecting other circuits.
As for dimensions of tape-packaged products, refer to page 44 .
s Operating Explanation
<Alternating magnetic field-type>
s Electrical Characteristics
Parameter
Operating magnetic flux density
Hysteresis breadth
Operating voltage
Supply current
Low level output voltage
Output leakage current
Operating point temperature drift
BRP 0 BOP
+B
Magnetic flux density
Symbol
BOP
BRP
BH
VCC
ICC
VOL
IOH
∆BOP
VCC=16V
VOO=16V
RL=10kΩ
Conditions
VCC=16V, B=<-10mT
IO=4mA, B>=10mT
VCC=16V, B=<10mT, VOO=16V
VCC=16V, Ta=-20˚C to +80˚C
MIN.
-
-10
-
4.5
-
-
-
-6
TYP.
-
-
-
-
-
-
-
-
(Ta=25˚C)
MAX. Unit
10
mT
-
mT
5
mT
16
V
10.5 mA
0.4
V
10
µA
6
mT
In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that may occur in equipment using any SHARP devices
shown in catalogs, data books, etc. Contact SHARP in order to obtain the latest device spcification sheets before using any SHARP device.