English
Language : 

GP2Y0A02 Datasheet, PDF (1/4 Pages) Sharp Electrionic Components – LONG DISTANCE MEASURING SENSOR
GP2Y0A02YK
GP2Y0A02YK
Long Distance Measuring
Sensor
I Features
1. Less influence on the colors of reflected objects and their
reflectivity, due to optical triangle measuring method
2. Distance output type
(Detection range:20 to 150cm)
3. An external control circuit is not necessary
Output can be connected directly to a microcomputer
I Applications
1. For detection of human body and various types of objects in
home appliances, OA equipment, etc
I Absolute Maximum Ratings
(Ta=25°C)
Parameter
Symbol
Rating
Unit
Supply voltage
*1 Output terminal voltage
VCC
−0.3 to +7 V
VO −0.3 to VCC +0.3 V
Operating temperature
Topr
−10 to +60 °C
Storage temperature
Tstg
−40 to +70 °C
*1 Open collector output
I Recommended Operating Conditions
Parameter
Symbol Rating Unit
Operating Supply voltage VCC 4.5 to 5.5
V
I Outline Dimensions
4-R1.75
R3.75
37
29.5
#4.475
#19.8±0.1
4-R1.75
Light detector
side
R3.75
(Unit : mm)
Lens case
φ3.2
Light emitter
side
10.1
8.95
10.45
φ3.2
Connector
PWB
3.3
1.2
13
❈ The dimensions marked # are
described the dimensions of
lens center position.
❈ Unspecified tolerance : ±0.3mm
Terminal connection
1 VO
2 GND
3 VCC
Notice In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that may occur in equipment using any SHARP
devices shown in catalogs, data books, etc. Contact SHARP in order to obtain the latest device specification sheets before using any SHARP device.
Internet Internet address for Electronic Components Group http://sharp-world.com/ecg/