s Absolute Maximum Ratings
(Ta=25°C)
Parameter
Symbol
Rating
Unit
Supply voltage
*1 Output terminal voltage
Operating temperature
VCC
−0.3 to +7 V
VO −0.3 to VCC +0.3 V
Topr
−10 to +60 °C
Storage temperature
Tstg
−40 to +70 °C
*1 Open collector output
s Recommended Operating Conditions
Parameter
Symbol Rating Unit
Operating Supply voltage VCC 4.5 to 5.5
V
s Outline Dimensions
(Unit : mm)
54.5
φ3.2 hole
37
29.5
520±0.1
Light detector side
R3.75
6.3 Lens case
2
R3.75
3.75
Light emitter side 10.1
14.75
7.5 4.15 16.3
φ3.2 hole
Connector 1.2
Made by
J.S.T. MFG,
3.3
CO., LTD.
S3B-PH
PWB
13
❈ The dimensions marked 5are
described the dimensions of
lens center position.
❈ Unspecified tolerance : ±0.3mm
Terminal connection
1 VO
2 GND
3 VCC