English
Language : 

GP1UM281QK Datasheet, PDF (1/7 Pages) Sharp Electrionic Components – Anti Electromagnetic Induction Noise Type Compact IR Detecting Unit for Remote Control
GP1UM26RK/27RK/28RK/28QK Series
GP1UM26RK/GP1UM27RK Series Anti Electromagnetic Induction
GP1UM28RK/GP1UM28QK Series Noise Type Compact IR Detecting
Unit for Remote Control
s Features
1. Anti electromagnetic induction noise type.
2. Compact (case volume).
3. Various B.P.F. (Band Pass Frequency) frequency to meet different
user needs.
s Applications
1. AV equipments
2. Home appliances
s Outline Dimensions
GP1UM26RK Series
5.6
2.2
5 3.6
GP1UM27RK Series
1.25
1.25
(Unit : mm)
8.6±0.5
*13.6±0.5
0.7
0.7
123
0.5
*12.54
*12.54
1 VOUT
2 VCC
3 GND
Example of mounting drawing
from solder side (Reference)
*35.8
*32.9
*32.9
1.4
1.4
Center
of PD
3 2 1 3−φ0.8
2.54
2.54
1.*1 : Indicates root dimensions of connector.
2.Unspecified tolerance : ±0.3
3.Case thickness : 0.3TYP
4.*2 : Exclude sagged solder
5.*3 : If there are difficulties to insert the GP1UM26RK series on PCB,
we recommend to expand +0.1mm from original 2.9mm.
5.6
2.2
10.2 3.6
13.8±0.5
*23.6±0.5
0.8
0.8
0.5
123
*12.54
*12.54
1 VOUT
2 VCC
3 GND
Example of mounting drawing
from solder side (Reference)
*35.8
*32.9
*32.9
1.4
1.4
Center
of PD
3 2 1 3−φ0.8
2.54
2.54
1.*1 : Indicates root dimensions of connector.
2.Unspecified tolerance : ±0.3
3.Case thickness : 0.3TYP
4.*2 : Exclude sagged solder
5.*3 : If there are difficulties to insert the GP1UM27RK series on PCB,
we recommend to expand +0.1mm from original 2.9mm.
Notice In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that may occur in equipment using any SHARP
devices shown in catalogs, data books, etc. Contact SHARP in order to obtain the latest device specification sheets before using any SHARP device.
Internet Internet address for Electronic Components Group http://sharp-world.com/ecg/