English
Language : 

HDUM100 Datasheet, PDF (4/4 Pages) Sensortechnics GmbH – Basic pressure sensors
HDU Series
Basic pressure sensors
PHYSICAL DIMENSIONS and electrical connection (cont.)
HDU...DF... (DIP, 2 ports same side, differential pressure)
11,90
3,41
2,54
5,08
6,23
9,28
Pin
Connection
1
+Vs
2
GND1
3
+Vs
4
-Vout
5
GND2
6
+Vout
Note:
The polarity indicated is for
pressure applied to high
pressure port.
0,46
7,60
18,75
19,50
low pressure
port
456
high pressure
port
321
pin marking
first angle projection
dimensions in mm
ORDERING INFORMATION
Options
Example:
Series
HDU
HDU
Pressure range
Pressure mode
M100
100 mbar A* Absolute
M350
350 mbar D Differential
B001
1 bar G Gage
B2x5
2.5 bar
B005
5 bar
P001
1 psi
P005
5 psi
P015
15 psi
P030
30 psi
P070
70 psi
* only available from
1 bar/15 psi onwards
B001
G
Housing
F* DIP, 2 ports
same side
Z** DIP, 1 port
axial
* standard for differential
devices, "D"
** standard for absolute
and gage devices,
"A" and "G"
Z
Options
P Prime grade
P
First Sensor reserves the right to make changes to any products herein. First Sensor does not assume any liability arising out of the
application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.
E / 11803 / D
4/4
www.first-sensor.com
www.sensortechnics.com