English
Language : 

XPC15GFH Datasheet, PDF (2/6 Pages) Sensortechnics GmbH – Precision compensated pressure sensors / mV-output
XPC/XPCL Series H-grade
Precision compensated pressure sensors / mV-output
SPECIFICATIONS
Maximum ratings (for all devices)
Supply voltage VS
Lead temperature (soldering 5 seconds)
Common mode pressure
3 to 16 V
315°C
50 psig
Environmental specifications (for all devices)
Temperature range
Compensated
Operating
Storage
Humidity limits (non-condensing)
0 to 70°C
-25 to 85°C
-40 to 125°C
0 to 95 %RH
PRESSURE SENSOR CHARACTERISTICS
VS = 12 V, TA = 25°C, pressure applied to port P17
Part no.
XPCL10...
XPC0.3...
XPC01...
XPC05...
XPC15...
XPC30...
XPC60...
XPC100...
XPC150...
Operating
pressure
10 "H2O
0.3 psi
1 psi
5 psi
15 psi
30 psi
60 psi
100 psi
150 psi
Proof
pressure1
3 psi
3 psi
3 psi
15 psi
45 psi
90 psi
180 psi
250 psi
250 psi
Burst
pressure2
5 psi
5 psi
5 psi
25 psi
75 psi
150 psi
300 psi
400 psi
400 psi
Full scale span3
Min.
Typ.
Max.
19.5 mV
19.5 mV
17.5 mV
20 mV
20 mV
18 mV
20.5 mV
20.5 mV
18.5 mV
59 mV
89 mV
89 mV
89 mV
99 mV
60 mV
90 mV
90 mV
90 mV
100 mV
61 mV
91 mV
91 mV
91 mV
101 mV
89 mV
90 mV
91 mV
PERFORMANCE CHARACTERISTICS
VS = 12 V, TA = 25°C, pressure applied to port P17
Characteristics
Min.
Typ.
Max.
Unit
Zero pressure offset
Combined non-linearity and hysteresis4
Temperature effects (0 to 70°C)5
Span
-0.5
0
+0.5
mV
±0.25
±0.5
%FSS
±1.0
Offset
±0.5
mV
Input resistance
Output resistance
5
kΩ
3
Response time (10 to 90 %FSS)
XPCL...
500
µs
XPC...
100
Common mode voltage6
6
V
Notes
1 Proof pressure is the maximum pressure which may be applied without causing durable shifts of the electrical parameters of the sensing element.
2 Burst pressure is the maximum pressure which may be applied without causing damage to the sensing element or leaks from the housing.
3 Full scale span is the algebraic difference between the output voltage at full-scale pressure and the output at zero pressure.
The span is ratiometric to the supply voltage.
4 Non-linearity refers to the Best Straight Line fit measured for offset pressure, full-scale pressure and ½ full-scale pressure.
5 Shift is relative to 25°C.
6 This is the common-mode voltage of the output arms (pins 2 and 4) for VS = 12 V.
7 For backside port devices (XPC...B...) pressure applied to P2.
2/6
June 2008 / 616
www.sensortechnics.com