English
Language : 

HDOM010AE8H Datasheet, PDF (2/5 Pages) Sensortechnics GmbH – Precision compensated pressure sensors
HDO Series
Precision compensated pressure sensors
PRESSURE RANGES SPECIFICATIONS1
Part number
HDOM010...P
HDOM020...P
HDOM050...P
HDOM100...P
HDOM200...P
HDOM500...P
HDOB001A...P
HDOB001(D,G)...P
HDOB002...P
HDOB005...P
HDOM010...H
HDOM020...H
HDOM050...H
HDOM100...H
HDOM200...H
HDOM500...H
HDOB001A...H
HDOB001(D,G)...H
HDOB002...H
HDOB005...H
Operating
pressure
0...10 mbar
0...20 mbar
0...50 mbar
0...100 mbar
0...200 mbar
0...500 mbar
0...1 bara
0...1 bar
0...2 bar
0...5 bar
0...10 mbar
0...20 mbar
0...50 mbar
0...100 mbar
0...200 mbar
0...500 mbar
0...1 bara
0...1 bar
0...2 bar
0...5 bar
Proof
pressure11
100 mbar
100 mbar
250 mbar
250 mbar
1 bar
1 bar
3 bara
3 bar
4 bar
7 bar
100 mbar
100 mbar
250 mbar
250 mbar
1 bar
1 bar
3 bara
3 bar
4 bar
7 bar
Burst
pressure12
150 mbar
150 mbar
500 mbar
500 mbar
1.4 bar
1.4 bar
5 bara
5 bar
6 bar
7 bar
150 mbar
150 mbar
500 mbar
500 mbar
1.4 bar
1.4 bar
5 bara
5 bar
6 bar
7 bar
Full-scale span2
Min.
Typ.
Max.
19.7 mV 20.0 mV 20.3 mV
24.7 mV 25.0 mV 25.3 mV
19.7 mV 20.0 mV 20.3 mV
19.7 mV 20.0 mV 20.3 mV
Specifications available on request.
Please contact Sensortechnics.
89.1 mV 90.0 mV 90.9 mV
Specifications available on request.
Please contact Sensortechnics.
19.5 mV
24.5 mV
19.37 mV
19.37 mV
20.0 mV
25.0 mV
20.0 mV
20.0 mV
20.5 mV
25.5 mV
20.63 mV
20.63 mV
Specifications available on request.
Please contact Sensortechnics.
86.85 mV 90.0 mV 93.15 mV
Specifications available on request.
Please contact Sensortechnics.
Specification notes:
1. Reference conditions: supply voltage, VS = 12VDC; TA = 25°C; common mode line pressure = 0 bar; pressure applied to high
pressure port.
2. Span is the algebraic difference between the output voltage at full scale pressure and the output at zero pressure. Span is
ratiometric to the supply voltage.
3. Hysteresis is the maximum output difference at any point within the operating pressure range for increasing and decreasing
pressure.
4. Maximum error band of the offset voltage and the error band of the span, relative to the 25°C reading.
5. Maximum difference in output at any pressure within the operating pressure range and temperature within 0 to +50°C after:
a) 100 temperature cycles, 0 to +50°C.
b) 1.0 million pressure cycles, 0 psi to full scale span.
6. Input impedance is the impedance between VS and ground.
7. Output impedance is the impedance between + and - outputs.
8. This is the common mode voltage of the output arms for VS = 12 VDC.
9. Response time for a zero to full scale span pressure step change, 10 to 90 % rise time.
10. Long term stability over a one year period.
11. Proof pressure is the maximum pressure which may be applied without causing durable shifts of the electrical parameters
of the sensing element.
12. Burst pressure is the maximum pressure which may be applied without causing damage to the sensing element or leaks to
the housing.
E / 11648 / A
2/5
www.sensortechnics.com