English
Language : 

HCA0611ARH8 Datasheet, PDF (2/7 Pages) Sensortechnics GmbH – Miniature amplified barometric pressure sensors
HCA-BARO Series
Miniature amplified barometric pressure sensors
PERFORMANCE CHARACTERISTICS
(Vs = 5.0 V, TA = 25 °C, analog output signal is ratiometric to VS, digital output signal is not ratiometric to VS,
pressure applied to high pressure port)
Characteristics
Min.
Typ.
Operating pressure range
HCA0611AR...
600
HCA0811AR...
800
Total accuracy (0 ... 85 °C)1
Response delay5, 6
2
A/D resolution6
15
D/A resolution
Current consumption (no load)7
5
D IGITA L P E RF ORMA NC E C HA RA C TE RIS TIC S
Output at min. pressure
0560
0666
Full scale span (FSS)2
6666
Full scale output
6BC6
6CCC
A NA LOGUE P E RF ORMA NC E C HA RA C TE RIS TIC S
Output at min. pressure
0.21
0.25
Full scale span (FSS)2
4.00
Full scale output
4.21
4.25
Max.
1100
1100
±1.0
11
076C
6DD2
0.29
4.29
Unit
mbara
%FSS
ms
bit
mA
Count Hex
V
Specification notes:
1. Total accuracy is the combined error from offset and span calibration, linearity, pressure hysteresis, and temperature
effects. Linearity is the measured deviation based on a straight line. Hysteresis is the maximum output difference at
any point within the operating pressure range for increasing and decreasing pressure. Calibration errors include the
deviation of offset and full scale from nominal values.
2. Full Scale Span (FSS) is the algebraic difference between the output signal for the highest and lowest specified
pressure.
3. Proof pressure is the maximum pressure which may be applied without causing durable shifts of the electrical parameters
of the sensing element.
4. Burst pressure is the maximum pressure which may be applied without causing damage to the sensing element or leaks to
the housing.
5. Max. delay time between pressure change at the pressure die and signal change at the output.
6. The response time depends on the adjusted internal A/D resolution of the sensor. For 15 bit it is typ. 2 ms. Other A/D
resolutions and reponse times are available on request. Please contact Sensortechnics for further information.
7. Sensors with lower current consumption are available on request. Please contact Sensortechnics for further information.
E / 11641 / F
2/7
www.first-sensor.com
www.sensortechnics.com