English
Language : 

DC001NGC4 Datasheet, PDF (2/6 Pages) Sensortechnics GmbH – SURSENSETM precision very low pressure sensors / V-output
DC Series
SURSENSETM precision very low pressure sensors / V-output
SPECIFICATIONS
Maximum ratings (for all devices)
Supply voltage V
S
4.9 to 5.1 V (DC...C4)
7 to 30 V (DC...R4, DC...R5)
Lead temperature (soldering 5 sec.)
315 °C
Maximum load current
Source
2 mA
Sink
20 µA
Environmental specifications (for all devices)
Temperature range
Compensated
Operating
Storage
Humidity limits (non-condensing)
0 to 50°C
-25 to +85°C
-40 to +125°C
0 to 95 %RH
CAUTION
Applications requiring supply voltages greater than 20 V on power-up must have a 10 Ohm resistor installed
between pin 1 of the sensor and the positiv (+) lead of the power supply.
If the sensor is subjected to a supply voltage of >20 V without ramp up, a current spike may occur causing the
operational amplifier and/or the ASIC to fail.
Do not operate above 30 V max. Due to internal component ratings, the maximum safe operating voltage
specification is 30 V.
PRESSURE SENSOR CHARACTERISTICS
Part no.
DC001N...
DC002N...
DC2R5N...
DC005N...
DC010N...
DC020N...
DC030N...
DC2R5B...
DC005B...
DC010B...
DC025B...
DC050B...
DC075B...
Pressure ranges
1 "H2O
2 "H O
2
2.5 "H2O
5 "H2O
10 "H2O
20 "H2O
30 "H2O
2.5 mbar
5 mbar
10 mbar
25 mbar
50 mbar
75 mbar
Proof pressure1
100 "H2O
100 "H O
2
100 "H2O
150 "H2O
150 "H2O
300 "H2O
450 "H2O
250 mbar
250 mbar
375 mbar
375 mbar
750 mbar
1125 mbar
Burst pressure2
200 "H2O
200 "H O
2
200 "H2O
300 "H2O
300 "H2O
450 "H2O
600 "H2O
500 mbar
500 mbar
750 mbar
750 mbar
1125 mbar
1500 mbar
Notes
1 Proof pressure is the maximum pressure which may be applied without causing durable shifts of the electrical parameters of the sensing element.
2 Burst pressure is the maximum pressure which may be applied without causing damage to the sensing element or leaks from the housing.
2/6
January 2008 / 564
www.sensortechnics.com