140PC...-PCB Series
Signal conditioned precision pressure transducers
PERFORMANCE CHARACTERISTICS
(unless otherwise noted VS = 8.00 ±0.01 V, RL > 100 kΩ, tamb = 25°C)
Characteristics
Min.
Operating pressure
vacuum gage devices2
differential devices3
absolute devices3
pressure/vacuum devices3
Zero pressure offset
Full scale span4
Full scale output
141PC01G-PCB
141PC05G-PCB
141PC15G-PCB
141PC30G-PCB
141PC100G-PCB
142PC01D-PCB
142PC05D-PCB
142PC15D-PCB
142PC30D-PCB
142PC100D-PCB
142PC150D-PCB
142PC15A-PCB
142PC30A-PCB
142PC100A-PCB
143PC01D-PCB
143PC03D-PCB
143PC05D-PCB
143PC15D-PCB
141PC.../142PC...-PCB
143PC...-PCB
141PC.../142PC...-PCB
143PC...-PCB
-1
-5
-15
-30
-100
0
0
0
0
0
0
0
0
0
-1
-2.5
-5
-15
0.95
3.45
4.95
2.45
5.90
Output at lowest specified pressure
143PC...-PCB
Non-linearity and hysteresis (BSL)5
Thermal effects6
Combined offset and span (0 to 70°C)
Long term stability7
all 1 psi devices
all others
Response time (10 to 90%)
Current consumption
Radiated, radio frequency electromagnetic
field immunity (RFI) EN6100-4-3 grade 3,
80 to 1000 MHz,
10
80 % AMC (1 KHz)
Typ.
1.00
3.50
5.00
2.50
6.00
1.00
0.1
±1.5
±0.5
±0.1
0.1
4.5
Max. Unit
0
0
0
0
psig
(vacuum)
0
1
5
15
30
psid(g)
100
150
15
30
psia
100
1
2.5
5
psid(g)
15
1.05
3.55
5.05
2.55
V
6.10
0.5
±3.0
±1.0
%FSO
ms
mA
V/m
Specification notes:
1. Proof pressure is the maximum pressure which may be applied without causing damage to the sensing element.
2. The output signal of all 141PC...-PCB devices is proportional to the vacuum applied to port A, relative to port B, e. g. the
output signal increases when pressure is applied to port B relative to port A.
3. The output signal of all 142PC...D-PCB and 143PC...D-PCB devices is proportional to the pressure applied to port A, relative
to port B, e.g. the output signal increases when vacuum is applied to port B relative to port A.
4. Full scale span is the algebraic difference between the positive full scale output and the zero pressure offset.
5. Non-linearity refers to the Best Straight Line fit measured for offset pressure, full scale pressure and 1/2 full scale pressure.
6. Thermal effects tested and guaranteed from 0 - 70°C relative to 25°C. All specifications shown are relative to 25°C.
7. Change in output after one year or 1 million pressure cycles.