English
Language : 

RQUM050D Datasheet, PDF (1/4 Pages) Sensortechnics GmbH – Basic pressure sensors
RQU Series
Basic pressure sensors
FEATURES
· 0...50 mbar to 0...1 bar and
0...1 to 0...15 psi gage or differential
· High impedance bridge
· Surface mount miniature package
· Usable for wet/wet applications8
· Sensortechnics PRO services
MEDIA COMPATIBILITY
All media compatible with
port 1: - polyphtalamide
- silver-filled silicone
- silicon nitride
port 2: - polyphtalamide
- fluor-silicone
- silicon
SPECIFICATIONS
Maximum ratings
ELECTRICAL CONNECTION
Supply voltage
12 V
Temperature limits
Storage
Operating
-55 to +100°C
-40 to +85°C
Lead temperature (10 sec. soldering)
260°C
+Vs
1
4-
Humidity limits
Vibration (0 to 2000 Hz)
(qualification tested)
Mechanical shock
(qualification tested)
0...100 %RH
20 g sine
50 g
Output
2+
3
E / 11705 / A
1/4