English
Language : 

RBIP015AU Datasheet, PDF (1/9 Pages) Sensortechnics GmbH – Pressure sensors with analog and digital output
RBI Series
Pressure sensors with analog and digital output
FEATURES
· 0...10 inch H O to 0...100 psi,
2
0...±5 inch H2O to 0...±100 psi,
absolute, gage or differential pressure
· 0.5...4.5 V analog output and digital
readout via I2C-bus
· Precision ASIC signal conditioning
· Temperature compensated
· Sensortechnics PRO services
MEDIA COMPATIBILITY
To be used with non-corrosive, non-ionic working
fluids such as clean dry air, dry gases and the like.
SPECIFICATIONS
ELECTRICAL CONNECTION
Maximum ratings
Supply voltage VS
max. 6.50 VDC
Output current
Sink
Source
Lead temperature (2 - 4 sec.)
Temperature ranges
Compensated
Operating
Storage
Vibration
4.75 V to 5.25 VDC
2 mA
2 mA
250 °C
0 to +85 °C
-20 to +105 °C
-40 to +125 °C
10 g at 20 - 2000 Hz
+Vs
N/C
6
1
5 SCL
RBI
7 SDA
2 Vout
220 nF
84 3
15 nF
N/C
GND
Shock
RBAP...
RBAH...
100 g for 11 ms
50 g for 11 ms
Note:
Capacitor 220 nF required between +Vs
and GND and 15 nF between Vout and GND.
Caution!
The sensors are not reverse polarity protected.
Incorrect applications of excitation voltage or ground
to the wrong pin can cause electrical failure.
Application of supply voltage above the maximum
can cause electrical failure.
It is important to place the capacitors as close
to the pins as possible!
Pins 4, 6 and 8 are internal device connections
and should not be connected for any reason!
E / 11718 / A
1/9