English
Language : 

RBAP015AU Datasheet, PDF (1/6 Pages) Sensortechnics GmbH – Signal conditioned pressure sensors
RBA Series
Signal conditioned pressure sensors
FEATURES
· 0...10 inch H O to 0...100 psi,
2
0...±5 inch H2O to 0...±100 psi,
absolute, gage or differential pressure
· 0.5...4.5 V ratiometric output
· Precision ASIC signal conditioning
· Temperature compensated
· Sensortechnics PRO services
MEDIA COMPATIBILITY
To be used with non-corrosive, non-ionic working
fluids such as clean dry air, dry gases and the like.
SPECIFICATIONS
ELECTRICAL CONNECTION
Maximum ratings
Supply voltage VS
max. 6.50 VDC
Output current
Sink
Source
Lead temperature (2 - 4 sec.)
Temperature ranges
Compensated
Operating
Storage
Vibration
4.75 V to 5.25 VDC
2 mA
2 mA
250 °C
0 to +85 °C
-20 to +105 °C
-40 to +125 °C
10 g at 20 - 2000 Hz
N/C
5 6 7 1 +Vs
RBA 2 Vout
84
3 GND
15 nF
220 nF
N/C
Shock
RBAP...
RBAH...
100 g for 11 ms
50 g for 11 ms
Note: Capacitor 220 nF required
between +Vs and GND and
15 nF between Vout and GND.
Caution!
The sensors are not reverse polarity protected.
Incorrect applications of excitation voltage or ground
to the wrong pin can cause electrical failure.
Application of supply voltage above the maximum
can cause electrical failure.
It is important to place the
capacitors as close to the pins
as possible!
Pins 4, 5, 6, 7 and 8 are internal
device connections and should
not be connected for any reason!
E / 11717 / A
1/6