English
Language : 

AWM720P1 Datasheet, PDF (1/4 Pages) Sensortechnics GmbH – Mass flow sensor for gases
FEATURES
· Ranges 0...200 slpm1
· Actual mass flow sensing
· 1...5 V output
SERVICE
To be used with dry gases only
The AWM series is NOT designed for liquid
flow and will be damaged by liquid flow through
the sensor
AWM700 Series
Mass flow sensor for gases
SPECIFICATIONS
Maximum ratings
Supply voltage2
Power consumption
Output load
NPN (Sinking)
PNP (Sourcing)
Temperature limits
Operating
Storage
Mechanical shock
ELECTRICAL CONNECTION
8 to 15 V
typ. 10 ±0.01 V
60 mW
10 mA
20 mA
-25 to 85°C
-40 to 90°C
100 g (3 drops, 3 axes)
4321
Pin 1: N/A
Pin 2: GND
Pin 3: +Vs
Pin 4: Vout
4321
Note:
Device will be supplied
with electrical connector
Note:
1 SLPM denotes standard liters per minute, which is a flow measurement referenced to standard conditions of 0°C, 1 bar, 50% RH.
2 Output voltage is ratiometric to supply voltage
August 2008 / 585
1/4
www.sensortechnics.com