TYPICAL APPLICATIONS (cont.)
Step-Up Rechargeable Battery Charger
SC1766
** CHARGING CURRENT = 0.8A, AUTO CUT-OFF AT 0.25% - DELTA-V POINT AND FAULT CONDITIONS (RIF SETS THE CHARGING CURRENT).
** VIN MUST BE LOWER THAN VBAT.
** SHORT CIRCUIT CONDITION IS PROTECTED WITH A 2A FUSE.
Step-Up/Down Rechargeable Battery Charger
** FAST CHARGE CURRENT =0.8A @VIN < VBAT, = (VIN - VBAT - 0.5)/0.82 @ VIN> VBAT.
TRICKLE CHARGE CURRENT = 30mA (RIF SETS FAST CHARGE CURRENT, RIT SETS TRICKLE CHARGE CURRENT).
** TYPICAL EFFICIENCY = 75%
** WITH SHORT CIRCUIT PROTECTION.
© 1997 SEMTECH CORP.