English
Language : 

SC4612H Datasheet, PDF (2/21 Pages) Semtech Corporation – 40V Synchronous Buck Controller
SC4612H
POWER MANAGEMENT
Absolute Maximum Ratings
Exceeding the specifications below may result in permanent damage to the device, or device malfunction. Operation outside of the parameters specified in
the Electrical Characteristics section is not implied.
Parameter
Symbol
Maximum
Units
Bias Supply Voltage to GND
VDD
-0.3 to 45
V
PHASE to GND
VIN
-2 to +55
V
DRV, ILIM, DL to GND, BST, DH to PHASE
-0.3 to 10
V
EAO, SS/EN, FB, OSC to GND
-0.3 to +5
V
DRV Source Current (peak)
100
mA
Thermal Resistance Junction to Ambient (MLPD) (1)
θJA
45.3
°C/W
Thermal Resistance Junction to Case (MLPD)
θJC
11
°C/W
Thermal Resistance Junction to Ambient (SOIC) (1)
θJA
115
°C/W
Thermal Resistance Junction to Case (SOIC)
θJC
45
°C/W
Storage Temperature Range
TSTG
-65 to +150
°C
Peak IR Reflow Temperature (10-40s)
TIR Reflow
260
°C
Lead Temperature (10s), (SOIC-14)
TLEAD
300
°C
All voltages with respect to GND. Positive currents are into, and negative currents are out of the specified terminal. Pulsed
is defined as a less than 10% duty cycle with a maximum duration of 500ns. Consult Packaging Section of Data sheet for
thermal limitations and considerations of packages.
Note:
(1). ThetaJA is calculated from a package in still air, mounted to a 3” x 4.5”, 4 layer FR4PCB with thermal vias (if applicable)
per JESD51 standards.
Recommended Operating Conditions
Performance is not guaranteed if the conditions below are exceeded.
Parameter
Symbol
Supply Voltage Range
VDD
Ambient Temperature Range
TA
Junction Temperature Range
TJ
Conditions
Min Typ Max Units
5
40
V
-40
105
oC
-40
125
oC
© 2008 Semtech Corp.